1-Hexen-3-one

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-FFAPDB-WaxFFAPFFAPFFAP
Column length (m) 30. 25.30.30.
Carrier gas   HeHeHe
Substrate      
Column diameter (mm) 0.32 0.320.320.32
Phase thickness (μm) 0.25 0.250.250.25
Program 40C(2min) => 40C/min => 60C(2min) => 6C/min => 180C => 15C/min => 230C(10min)not specified35C(2min) => 40C/min => 60C(2min) => 6C/min => 230C35C (2min) => 40C/min => 60C (2min) => 6C/min => 180C => 10C/min => 240C35C (2min) => 40C/min => 60C (2min) => 6C/min => 180C => 10C/min => 240C
I 1086.1091.1086.1101.1101.
ReferenceBuettner, 2007Peterson and Reineccius, 2003Zehentbauer and Grosch, 1998Schermann and Schieberle, 1997Schermann and Schieberle, 1997
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase Supelcowax 10Supelcowax 10FFAP
Column length (m) 60.60. 
Carrier gas HeliumHelium 
Substrate    
Column diameter (mm) 0.250.25 
Phase thickness (μm) 0.250.25 
Program 60 0C (10 min) 2 0C/min -> 80 0C 3 0C/min -> 100 0C 4 0C/min -> 220 0C (30 min)not specifiednot specified
I 1092.1103.1120.
ReferenceCastioni and Kapetanidis, 1996Castioni and Kapetanidis, 1996Blank, Stampfli, et al., 1994
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Buettner, 2007
Buettner, A., A selective and sensitive approach to characterize odour-active and volatile constituents in small-scale human milk samples, Flavour Fragr. J., 2007, 22, 6, 465-473, https://doi.org/10.1002/ffj.1822 . [all data]

Peterson and Reineccius, 2003
Peterson, D.G.; Reineccius, G.A., Determination of the aroma impact compounds in heated sweet cream butter, Flavour Fragr. J., 2003, 18, 4, 320-324, https://doi.org/10.1002/ffj.1228 . [all data]

Zehentbauer and Grosch, 1998
Zehentbauer, G.; Grosch, W., Crust aroma of baguettes. I. Key odorants of baguettes prepared in two different ways, J. Cereal Science, 1998, 28, 1, 81-92, https://doi.org/10.1006/jcrs.1998.0184 . [all data]

Schermann and Schieberle, 1997
Schermann, P.; Schieberle, P., Evaluation of key odorants in milk chocolate and cocoa mass by aroma extract dilution analyses, J. Agric. Food Chem., 1997, 45, 3, 867-872, https://doi.org/10.1021/jf960670h . [all data]

Castioni and Kapetanidis, 1996
Castioni, P.; Kapetanidis, I., Volatile constituents from Brunfelsia grandiflora ssp. grandiflora: qualitative analysis by GC-MS, Scientia Pharmaceutica, 1996, 64, 83-91. [all data]

Blank, Stampfli, et al., 1994
Blank, I.; Stampfli, A.; Eisenreich, W., Analysis of food flavourings by gas chromatography - olfactometry in Trends of Flavour Research, Maarse, H.; van der Heij, D.G., ed(s)., 1994, 271-276. [all data]


Notes

Go To: Top, Normal alkane RI, polar column, custom temperature program, References