Octane, 2,2-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHPONAPONAUltra-1Petrocol DH
Column length (m) 50.50.50. 100.
Carrier gas He   He
Substrate      
Column diameter (mm) 0.250.20.2 0.25
Phase thickness (μm) 0.50.50.5 0.5
Tstart (C) 35.35.35.-40.30.
Tend (C) 200.220.220.230.220.
Heat rate (K/min) 3.1.1.4.1.
Initial hold (min) 10.0.50.5  
Final hold (min) 10.8.8.  
I 920.917.6920.3919.919.
ReferenceCensullo, Jones, et al., 2003Martos, Saraullo, et al., 1997Martos, Saraullo, et al., 1997Olson, Sinkevitch, et al., 1992White, Hackett, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-101
Column length (m) 108.
Carrier gas  
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm) 0.2
Tstart (C) 35.
Tend (C) 200.
Heat rate (K/min) 1.
Initial hold (min)  
Final hold (min)  
I 918.
ReferenceHayes and Pitzer, 1981
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Censullo, Jones, et al., 2003
Censullo, A.C.; Jones, D.R.; Wills, M.T., Speciation of the volatile organic compounds (VOCs) in solventborne aerosol coatings by solid phase microextraction-gas chromatography, J. Coat. Technol., 2003, 75, 936, 47-53, https://doi.org/10.1007/BF02697922 . [all data]

Martos, Saraullo, et al., 1997
Martos, P.A.; Saraullo, A.; Pawliszyn, J., Estimation of air/coating distribution coefficients for solid phase microextraction using retention indexes from linear temperature-programmed capillary gas chromatography. Application to the sampling and analysis of total petroleum hydrocarbons in air, Anal. Chem., 1997, 69, 3, 402-408, https://doi.org/10.1021/ac960633p . [all data]

Olson, Sinkevitch, et al., 1992
Olson, K.L.; Sinkevitch, R.M.; Sloane, T.M., Speciation and Quantitation of Hydrocarbons in Gasoline Engine Exhaust, J. Chromatogr. Sci., 1992, 30, 12, 500-508, https://doi.org/10.1093/chromsci/30.12.500 . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Hayes and Pitzer, 1981
Hayes, P.C., Jr.; Pitzer, E.W., Kovats indices as a tool in characterizing hydrocarbon fuels in temperature programmed glass capillary gas chromatography. Part 1. Qualitative identification, Inhouse rpt. for Air Force Wright Aeronautical Labs., Air Force Wright Aeronautical Labs., Wright-Patterson AFB, Ohio, 1981, 75. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References