Cyclohexene, 1-octyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PEG 4000PEG 4000PEG 4000PEG 4000PEG 4000
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 100.110.120.150.160.
I 1583.1595.1600.1612.1617.
ReferenceRang, Orav, et al., 1988Rang, Orav, et al., 1988Rang, Orav, et al., 1988Rang, Orav, et al., 1988Rang, Orav, et al., 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PEG-20MPEG-20MPEG-20MPEG-20MPEG-20M
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 100.120.130.140.150.
I 1567.1580.1586.1592.1598.
ReferenceRang, Orav, et al., 1988Rang, Orav, et al., 1988Rang, Orav, et al., 1988Rang, Orav, et al., 1988Rang, Orav, et al., 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PEG-20MPEG-20MPEG-20MPEG-20MPEG-20M
Column length (m)  100.100.100.100.
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm)  0.250.250.250.25
Phase thickness (μm)      
Temperature (C) 160.120.130.140.150.
I 1603.1580.51586.31592.1598.1
ReferenceRang, Orav, et al., 1988Orav, Kuningas, et al., 1982Orav, Kuningas, et al., 1982Orav, Kuningas, et al., 1982Orav, Kuningas, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase PEG-20MPEG 4000
Column length (m) 100.45.
Carrier gas HeNitrogen or Helium
Substrate   
Column diameter (mm) 0.250.25
Phase thickness (μm)   
Temperature (C) 160.100.
I 1602.81583.
ReferenceOrav, Kuningas, et al., 1982Rang, Orav, et al., 1977
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Rang, Orav, et al., 1988
Rang, S.A.; Orav, A.E.; Kuningas, K.R.; Meister, A.E.; Strense, T.V.; Eisen, O.G., Gas-Chromatographic Characteristics of unsaturated hydrocarbons, Academy of Sciences of Estonia SSR, Tallinn, Estonia SSR, 1988, 208. [all data]

Orav, Kuningas, et al., 1982
Orav, A.; Kuningas, K.; Rang, S.; Eisen, O., Capillary gas chromatography of monosubstituted cyclopentenes and cyclohexenes C8-C15 on polyethylene glycol 20M, Eesti NSV Tead. Akad. Toim. Keem., 1982, 40-49. [all data]

Rang, Orav, et al., 1977
Rang, S.; Orav, A.; Kuningas, K.; Eisen, O., Capillary Gas Chromatography of Monosubstituted Cyclopentenes and Cyclohexenes, Chromatographia, 1977, 10, 3, 115-122, https://doi.org/10.1007/BF02297862 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References