Titanium iodide


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (cal/mol*K)
    H° = standard enthalpy (kcal/mol)
    S° = standard entropy (cal/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. - 800.800. - 6000.
A 5.8720119.932541
B 14.732600.516127
C -16.35110-0.079295
D 6.3051300.005104
E 0.0190080.118302
F 63.2902062.58540
G 67.7428175.97070
H 65.5001065.50010
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1968 Data last reviewed in December, 1968
Temperature
(K)
Cp
(cal/mol*K)

(cal/mol*K)
-(G° - H°298.15)/T
(cal/mol*K)
H° - H°298.15
(kcal/mol)
298.9.1964.2564.25-0.00
300.9.2064.3164.250.02
400.9.6767.0264.620.96
500.10.0169.2265.331.95
600.10.2471.0766.132.96
700.10.3772.6666.953.99
800.10.4574.0567.765.03
Temperature
(K)
Cp
(cal/mol*K)

(cal/mol*K)
-(G° - H°298.15)/T
(cal/mol*K)
H° - H°298.15
(kcal/mol)
800.10.4874.0567.765.04
900.10.4875.2868.536.08
1000.10.4976.3969.267.13
1100.10.5177.3969.958.18
1200.10.5378.3170.619.23
1300.10.5579.1571.2410.29
1400.10.5779.9371.8311.34
1500.10.6080.6672.3912.40
1600.10.6281.3572.9313.46
1700.10.6581.9973.4514.53
1800.10.6782.6073.9415.59
1900.10.6983.1874.4116.66
2000.10.7283.7374.8617.73
2100.10.7484.2575.3018.81
2200.10.7684.7575.7119.88
2300.10.7885.2376.1220.96
2400.10.8185.6976.5122.04
2500.10.8386.1376.8823.12
2600.10.8586.5677.2524.20
2700.10.8686.9777.6025.29
2800.10.8887.3677.9426.38
2900.10.9087.7478.2727.46
3000.10.9288.1178.6028.56
3100.10.9388.4778.9129.65
3200.10.9588.8279.2130.74
3300.10.9789.1679.5131.84
3400.10.9889.4879.8032.94
3500.11.0089.8080.0834.03
3600.11.0190.1180.3535.14
3700.11.0290.4180.6236.24
3800.11.0490.7180.8837.34
3900.11.0591.0081.1438.44
4000.11.0691.2881.3939.55
4100.11.0791.5581.6340.66
4200.11.0991.8281.8741.76
4300.11.1092.0882.1142.87
4400.11.1192.3382.3443.98
4500.11.1292.5882.5645.10
4600.11.1392.8382.7846.21
4700.11.1493.0783.0047.32
4800.11.1593.3083.2148.44
4900.11.1693.5383.4249.55
5000.11.1793.7683.6250.67
5100.11.1893.9883.8251.79
5200.11.1994.1984.0252.91
5300.11.2094.4184.2154.03
5400.11.2294.6284.4155.15
5500.11.2394.8284.5956.27
5600.11.2495.0384.7857.39
5700.11.2595.2384.9658.52
5800.11.2695.4285.1459.64
5900.11.2795.6185.3160.77
6000.11.2895.8085.4961.90

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References