beryllium hydroxide


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1400.1400. to 6000.
A 62.9060296.46086
B 54.755177.604086
C -32.44228-1.374904
D 8.3829380.087302
E -1.174173-12.60120
F -701.4141-730.7942
G 288.5203317.4685
H -676.5528-676.5528
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in December, 1975 Data last reviewed in December, 1975
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.63.34233.9234.0-0.01
300.63.59234.3234.00.11
400.72.82254.0236.66.98
500.78.52270.9241.814.56
600.82.63285.6247.922.63
700.85.82298.6254.231.06
800.88.40310.3260.539.77
900.90.57320.8266.748.73
1000.92.43330.4272.657.88
1100.94.07339.3278.267.20
1200.95.57347.6283.776.69
1300.96.98355.3288.986.31
1400.98.38362.5293.996.08
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1400.98.22362.5293.996.08
1500.99.47369.3298.7106.0
1600.100.5375.8303.3116.0
1700.101.5381.9307.8126.1
1800.102.3387.7312.0136.3
1900.103.1393.3316.2146.5
2000.103.7398.6320.2156.9
2100.104.3403.7324.0167.3
2200.104.9408.5327.7177.7
2300.105.4413.2331.4188.2
2400.105.8417.7334.9198.8
2500.106.2422.0338.3209.4
2600.106.6426.2341.6220.0
2700.107.0430.2344.8230.7
2800.107.3434.1347.9241.4
2900.107.6437.9350.9252.2
3000.107.9441.6353.9263.0
3100.108.1445.1356.8273.8
3200.108.3448.5359.6284.6
3300.108.6451.9362.3295.4
3400.108.8455.1365.0306.3
3500.108.9458.3367.6317.2
3600.109.1461.3370.2328.1
3700.109.3464.3372.7339.0
3800.109.4467.2375.2349.9
3900.109.6470.1377.6360.9
4000.109.7472.9379.9371.8
4100.109.8475.6382.2382.8
4200.109.9478.2384.5393.8
4300.110.0480.8386.7404.8
4400.110.1483.3388.8415.8
4500.110.2485.8391.0426.8
4600.110.2488.2393.1437.8
4700.110.3490.6395.1448.9
4800.110.4492.9397.1459.9
4900.110.5495.2399.1470.9
5000.110.5497.4401.0482.0
5100.110.6499.6403.0493.0
5200.110.6501.8404.8504.1
5300.110.7503.9406.7515.2
5400.110.7506.0408.5526.2
5500.110.8508.0410.3537.3
5600.110.9510.0412.1548.4
5700.110.9511.9413.8559.5
5800.111.0513.9415.5570.6
5900.111.0515.8417.2581.7
6000.111.1517.6418.8592.8

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.