Nonanal

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1SE-30OV-101OV-101
Column length (m) 6.6.40.20.20.
Carrier gas HeHe   
Substrate      
Column diameter (mm) 0.3100.3100.350.50.5
Phase thickness (μm) 0.520.520.35  
Temperature (C) 20.20.100.150.180.
I 1079.11080.71085.41087.51093.3
ReferenceKoutek, Cvacka, et al., 2001Koutek, Cvacka, et al., 2001Tudor, 1997Cha and Lee, 1994Cha and Lee, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase Apiezon LApiezon L
Column length (m)   
Carrier gas   
Substrate Celite (40:60 Gewichtsverhaltnis)Celite (40:60 Gewichtsverhaltnis)
Column diameter (mm)   
Phase thickness (μm)   
Temperature (C) 130.190.
I 1069.1080.
Referencevon Kováts, 1958von Kováts, 1958
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Koutek, Cvacka, et al., 2001
Koutek, B.; Cvacka, J.; Streinz, L.; Vrkocová, P.; Doubský, J.; Simonová, H.; Feltl, L.; Svoboda, V., Comparison of methods employing gas chromatography retention data to determine vapour pressures at 298 K, J. Chromatogr. A, 2001, 923, 1-2, 137-152, https://doi.org/10.1016/S0021-9673(01)00965-7 . [all data]

Tudor, 1997
Tudor, E., Temperature dependence of the retention index for perfumery compounds on a SE-30 glass capillary column. I. Linear equations, J. Chromatogr. A, 1997, 779, 1-2, 287-297, https://doi.org/10.1016/S0021-9673(97)00453-6 . [all data]

Cha and Lee, 1994
Cha, K.-W.; Lee, D.-J., Prediction of retention indices of various compounds in gas-liquid chromatography, J. Korean Chem. Soc., 1994, 38, 2, 108-120, retrieved from http://journal.kcsnet.or.kr/publi/dh/dh94n2/108.pdf. [all data]

von Kováts, 1958
von Kováts, E., 206. Gas-chromatographische Charakterisierung organischer Verbindungen. Teil 1: Retentionsindices aliphatischer Halogenide, Alkohole, Aldehyde und Ketone, Helv. Chim. Acta, 1958, 41, 7, 1915-1932, https://doi.org/10.1002/hlca.19580410703 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References