1,4-Dioxane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedCapillaryCapillary
Active phase Polydimethyl siloxanePolydimethyl siloxanePolydimethyl siloxanePolydimethyl siloxanePolydimethyl siloxane
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 120.120.120.105.75.
I 696.696.698.694.690.
ReferenceTello, Lebron-Aguilar, et al., 2009Tello, Lebron-Aguilar, et al., 2009Tello, Lebron-Aguilar, et al., 2009Tello, Lebron-Aguilar, et al., 2009Tello, Lebron-Aguilar, et al., 2009
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxaneMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 90.100.120.140.80.
I 692.693.696.699.690.
ReferenceTello, Lebron-Aguilar, et al., 2009Lebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeDB-1Apieson L
Column length (m)    60. 
Carrier gas    Henot specified
Substrate     not specified
Column diameter (mm)    0.32 
Phase thickness (μm)    1. 
Temperature (C) 120.120.120.60.120.
I 696.696.697.680.694.
ReferenceLebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Lebrón-Aguilar, Quintanilla-López, et al., 2007Shimadzu, 2003Kurdina, Markovich, et al., 1969
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Apieson L
Column length (m)  
Carrier gas not specified
Substrate not specified
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 120.
I 694.
ReferenceKurdina, Markovich, et al., 1969
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tello, Lebron-Aguilar, et al., 2009
Tello, A.M.; Lebron-Aguilar, R.; Quintanilla-Lopez, J.E.; Santiuste, J.M., Isothermal retention indices on poly93-cyanopropylmethyl)siloxane stationary phases, J. Chromatogr. A, 2009, 1216, 10, 1630-1639, https://doi.org/10.1016/j.chroma.2008.10.025 . [all data]

Lebrón-Aguilar, Quintanilla-López, et al., 2007
Lebrón-Aguilar, R.; Quintanilla-López, J.E.; Tello, A.M.; Santiuste, J.M., Isothermal retention indices on poly (3,3,3-trifluoropropylmethylsiloxane) stationary phases, J. Chromatogr. A, 2007, 1160, 1-2, 276-288, https://doi.org/10.1016/j.chroma.2007.05.025 . [all data]

Shimadzu, 2003
Shimadzu, Gas chromatography analysis of organic solvents using capillary columns (No. 3), 2003, retrieved from http://www.shimadzu.com/apps/form.cfm. [all data]

Kurdina, Markovich, et al., 1969
Kurdina, Z.G.; Markovich, V.E.; Sakharov, V.M., Gas chromatography of cyclic O-containing compounds in Gas chromatography, Issue # 10, NIITEKhim, Moscow, 1969, 128-133. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, isothermal, References