Butanal

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)      
Temperature (C) 70.80.90.100.110.
I 854.46867.47874.62891.30911.46
ReferenceCiaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase HP-InnowaxHP-InnowaxHP-InnowaxHP-InnowaxCarbowax 4000
Column length (m) 30.30.30.30.10.
Carrier gas     N2
Substrate     GAS Chrom P
Column diameter (mm) 0.320.320.320.32 
Phase thickness (μm) 0.50.50.50.5 
Temperature (C) 110.50.70.90.105.
I 907.2894.8897.8901.8906.
ReferenceHéberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999Minyard, Tumlinson, et al., 1967
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ciaznska-Halarewicz and Kowalska, 2003
Ciaznska-Halarewicz, K.; Kowalska, T., A study of the dependence of the Kováts retention index on the temperature of analysis on stationary phases of different polarity, Acta Chromatogr., 2003, 13, 69-80. [all data]

Héberger and Görgényi, 1999
Héberger, K.; Görgényi, M., Principal component analysis of Kováts indices for carbonyl compounds in capillary gas chromatography, J. Chromatogr., 1999, 845, 1-2, 21-31, https://doi.org/10.1016/S0021-9673(99)00323-4 . [all data]

Minyard, Tumlinson, et al., 1967
Minyard, J.P.; Tumlinson, J.H.; Thompson, A.C.; Hedin, P.A., Constituents of the cotton bud. The carbonyl compounds, J. Agric. Food Chem., 1967, 15, 3, 517-524, https://doi.org/10.1021/jf60151a021 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References