Propanoic acid, phenylmethyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryPackedPackedPacked
Active phase SE-30SE-30SE-30OV-1OV-1
Column length (m) 40. 3.72.2.
Carrier gas    N2N2
Substrate   Chromosorb W AW DMCSGas Chrom QGas Chrom Q
Column diameter (mm) 0.35    
Phase thickness (μm) 0.35    
Temperature (C) 100.200.200.140.150.
I 1230.41245.1245.1259.1272.
ReferenceTudor, 1997Tarjan, Nyiredy, et al., 1989Haken, Hartley, et al., 1983Tomori, Kalasz, et al., 1974Tomori, Kalasz, et al., 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase OV-1
Column length (m) 2.
Carrier gas N2
Substrate Gas Chrom Q
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 160.
I 1284.
ReferenceTomori, Kalasz, et al., 1974
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tudor, 1997
Tudor, E., Temperature dependence of the retention index for perfumery compounds on a SE-30 glass capillary column. I. Linear equations, J. Chromatogr. A, 1997, 779, 1-2, 287-297, https://doi.org/10.1016/S0021-9673(97)00453-6 . [all data]

Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8 . [all data]

Haken, Hartley, et al., 1983
Haken, J.K.; Hartley, H.N.T.; Srisukh, D., Retention increments of aromatic esters, Chromatographia, 1983, 17, 11, 589-596, https://doi.org/10.1007/BF02261941 . [all data]

Tomori, Kalasz, et al., 1974
Tomori, E.; Kalasz, H.; Nagy, J.; Knoll, J., Gas Chromatographic Studies of Derivatives of Celluline-Like Substances, J. Chromatogr., 1974, 91, 113-118, https://doi.org/10.1016/S0021-9673(01)97890-2 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References