Cesium hydroxide


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. - 1200.1200. - 6000.
A 51.41216112.9730
B 122.992910.10323
C -89.85391-1.896826
D 25.973440.124260
E 0.178120-11.76035
F -707.3052-747.1160
G 391.0567462.7086
H -687.8496-687.8496
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in June, 1971 Data last reviewed in June, 1971
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.82.78360.7360.7-0.01
300.82.90361.3360.70.15
400.89.01386.0364.18.75
500.94.40406.4370.617.93
600.98.97424.0378.027.61
700.102.8439.6385.737.70
800.105.9453.5393.448.13
900.108.5466.1400.758.86
1000.110.7477.7407.969.82
1100.112.7488.3414.780.99
1200.114.6498.2421.392.35
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1200.114.4498.2421.392.35
1300.116.2507.5427.5103.9
1400.117.7516.1433.6115.6
1500.119.1524.3439.3127.4
1600.120.2532.0444.9139.4
1700.121.2539.3450.2151.5
1800.122.1546.3455.4163.6
1900.122.9552.9460.3175.9
2000.123.6559.2465.1188.2
2100.124.3565.3469.8200.6
2200.124.9571.1474.2213.1
2300.125.5576.6478.6225.6
2400.126.0582.0482.8238.2
2500.126.4587.1486.8250.8
2600.126.9592.1490.8263.4
2700.127.3596.9494.6276.1
2800.127.6601.5498.4288.9
2900.128.0606.0502.0301.7
3000.128.3610.4505.5314.5
3100.128.5614.6509.0327.3
3200.128.8618.7512.4340.2
3300.129.0622.6515.6353.1
3400.129.3626.5518.8366.0
3500.129.5630.2522.0378.9
3600.129.7633.9525.0391.9
3700.129.8637.4528.0404.9
3800.130.0640.9530.9417.9
3900.130.1644.3533.8430.9
4000.130.3647.6536.6443.9
4100.130.4650.8539.4456.9
4200.130.5653.9542.0470.0
4300.130.6657.0544.7483.0
4400.130.7660.0547.3496.1
4500.130.8663.0549.8509.1
4600.130.9665.8552.3522.2
4700.130.9668.6554.7535.3
4800.131.0671.4557.1548.4
4900.131.1674.1559.5561.5
5000.131.1676.8561.8574.6
5100.131.2679.3564.1587.7
5200.131.3681.9566.3600.9
5300.131.3684.4568.5614.0
5400.131.4686.9570.7627.1
5500.131.4689.3572.9640.3
5600.131.5691.6575.0653.4
5700.131.6694.0577.0666.6
5800.131.7696.2579.1679.7
5900.131.7698.5581.1692.9
6000.131.8700.7583.0706.1

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References