Benzenamine, N,N-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1OV-1OV-1OV-1OV-1
Column length (m)  50.25.24.30.
Carrier gas      
Substrate      
Column diameter (mm)  0.20.310.30.3
Phase thickness (μm)    1.11.1
Tstart (C) 35.35.35.35.35.
Tend (C) 300.280.280.250.250.
Heat rate (K/min) 8.  4.4.
Initial hold (min)  5.5.5.5.
Final hold (min)      
I 1065.41062.371062.071063.1062.71
ReferenceGautzsch and Zinn, 1996Knoppel, de Bortoli, et al., 1983Knoppel, de Bortoli, et al., 1983Knoppel, de Bortoli, et al., 1982Knoppel, de Bortoli, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase SE-30
Column length (m) 3.0
Carrier gas He
Substrate Celite 560
Column diameter (mm)  
Phase thickness (μm)  
Tstart (C) 100.
Tend (C) 250.
Heat rate (K/min) 20.
Initial hold (min)  
Final hold (min)  
I 1100.
ReferenceHaken and McKay, 1966
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

Knoppel, de Bortoli, et al., 1983
Knoppel, H.; de Bortoli, M.; Peil, A.; Vissers, H., Reproducibility of Temperature-Programmed Gas Chromatographic Retention Indices with Non-Polar Glass Capillary Columns, J. Chromatogr., 1983, 279, 483-492, https://doi.org/10.1016/S0021-9673(01)93649-0 . [all data]

Knoppel, de Bortoli, et al., 1982
Knoppel, H.; de Bortoli, M.; Peil, A.; Schauenburg, H.; Vissers, H., The determination of linear PTGC retention indices for use in environmental organics analysis, Comm. Eur. Communities, Rep. EUR, 1982, 99-109. [all data]

Haken and McKay, 1966
Haken, J.K.; McKay, T.R., The gas chromatographic analysis of N,N1-Dialkyl anilines and vinyl monomers in polyester resins, J. Gas Chromatogr., 1966, 4, 4, 132-133, https://doi.org/10.1093/chromsci/4.4.132 . [all data]