Benzene, 1,2,4-trichloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5SE-30HP-5HP-5
Column length (m) 60.60.  60.
Carrier gas HeHe  N2
Substrate      
Column diameter (mm) 0.320.32  0.25
Phase thickness (μm) 1.1.  0.25
Temperature (C) 120.120.160.120.120.
I 1193.561193.671193.01189.61199.7
ReferenceHarangi, 2003Harangi, 2003Santiuste, Harangi, et al., 2003Santiuste, Harangi, et al., 2003Santiuste J.M. and Takacs J.M., 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5DB-5DB-5DB-5SE-30
Column length (m) 60.30.30.30.25.
Carrier gas N2N2N2N2 
Substrate      
Column diameter (mm) 0.250.530.530.530.32
Phase thickness (μm) 0.251.51.51.5 
Temperature (C) 140.110.70.90.160.
I 1211.11189.561164.561176.181177.
ReferenceSantiuste J.M. and Takacs J.M., 2003Gerbino, Garbarino, et al., 1996Gerbino, Garbarino, et al., 1996Gerbino, Garbarino, et al., 1996Evans and Haken, 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase SE-30SE-30SE-30SE-30SE-30
Column length (m)  25.25.25.2.
Carrier gas  N2N2N2 
Substrate     Gaschrom Q
Column diameter (mm)  0.220.220.22 
Phase thickness (μm)      
Temperature (C) 160.120.140.160.100.
I 1193.1177.1183.1193.1186.
ReferenceTarjan, Nyiredy, et al., 1989Haken and Korhonene, 1983Haken and Korhonene, 1983Haken and Korhonene, 1983Winskowski, 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPacked
Active phase SE-30SE-30SE-30
Column length (m) 2.1.1.
Carrier gas    
Substrate Gaschrom QChromaton N-AW-GMDSChromaton N-AW-GMDS
Column diameter (mm)    
Phase thickness (μm)    
Temperature (C) 150.150.160.
I 1177.1161.1166.
ReferenceWinskowski, 1983Vylegzhanina and Keiser, 1976Vylegzhanina and Keiser, 1976
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Harangi, 2003
Harangi, J., Short communication. Retention index calculation without n-alkanes -- the virtual carbon number, J. Chromatogr. A, 2003, 993, 1-2, 187-195, https://doi.org/10.1016/S0021-9673(03)00320-0 . [all data]

Santiuste, Harangi, et al., 2003
Santiuste, J.M.; Harangi, J.; Takács, J.M., Mosaic increments for predicting the gas chromatographic retention data of the chlorobenzenes, J. Chromatogr. A, 2003, 1002, 1-2, 155-168, https://doi.org/10.1016/S0021-9673(03)00736-2 . [all data]

Santiuste J.M. and Takacs J.M., 2003
Santiuste J.M.; Takacs J.M., Relationships between retention data of benzene and chlorobenzenes with their physico-chemical properties and topological indices, Chromatographia, 2003, 58, 87-96. [all data]

Gerbino, Garbarino, et al., 1996
Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 1996, 86, 63-75. [all data]

Evans and Haken, 1989
Evans, M.B.; Haken, J.K., Dispersion and selectivity indices in gas chromatography. IV. Chlorinated aromatic compounds, J. Chromatogr., 1989, 468, 373-382, https://doi.org/10.1016/S0021-9673(00)96332-5 . [all data]

Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8 . [all data]

Haken and Korhonene, 1983
Haken, J.K.; Korhonene, I.O.O., Retention increments of isomeric chlorobenzenes, J. Chromatogr., 1983, 265, 323-327, https://doi.org/10.1016/S0021-9673(01)96727-5 . [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Vylegzhanina and Keiser, 1976
Vylegzhanina, G.F.; Keiser, L.S., Determination of the heats of solution of the insecticide gardona and its metabolites in the stationary phase and their Kovats retention indices, Zh. Anal. Khim., 1976, 31, 1, 171-173. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References