Benzene, 1,2,4-trichloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Condensed phase thermochemistry data

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
ALS - Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein
DH - Eugene S. Domalski and Elizabeth D. Hearing

Quantity Value Units Method Reference Comment
Δfliquid-50.2 ± 1.5kJ/molCcrYan, Gu, et al., 1987ALS
Quantity Value Units Method Reference Comment
Δcliquid-2810.5 ± 1.5kJ/molCcrYan, Gu, et al., 1987ALS
Δcliquid-2797.98 ± 0.44kJ/molCcrPlatonov and Simulin, 1985ALS

Constant pressure heat capacity of liquid

Cp,liquid (J/mol*K) Temperature (K) Reference Comment
194.90298.15Wilhelm, Lainez, et al., 1986DH
194.6298.15Wilhelm, Inglese, et al., 1982DH
188.297.95Petit and TerMinassian, 1974T = 297 to 454 K. Value is unsmoothed experimental datum.; DH

IR Spectrum

Go To: Top, Condensed phase thermochemistry data, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, References, Notes

Data compiled by: Coblentz Society, Inc.

Data compiled by: Tanya L. Myers, Russell G. Tonkyn, Ashley M. Oeck, Tyler O. Danby, John S. Loring, Matthew S. Taubman, Stephen W. Sharpe, Jerome C. Birnbaum, and Timothy J. Johnson

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director


Mass spectrum (electron ionization)

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, UV/Visible spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Chuck Anderson, Aldrich Chemical Co.
NIST MS number 107466

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


UV/Visible spectrum

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Victor Talrose, Alexander N. Yermakov, Alexy A. Usov, Antonina A. Goncharova, Axlexander N. Leskin, Natalia A. Messineva, Natalia V. Trusova, Margarita V. Efimkina

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

UVVis spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Source Jondorf and Williams, 1958
Owner INEP CP RAS, NIST OSRD
Collection (C) 2007 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin INSTITUTE OF ENERGY PROBLEMS OF CHEMICAL PHYSICS, RAS
Source reference RAS UV No. 5871
Instrument Unicam Spectrophotometer
Melting point 17
Boiling point 213.5

Gas Chromatography

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), UV/Visible spectrum, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryDB-5120.1193.56Harangi, 200360. m/0.32 mm/1. μm, He
CapillaryDB-5120.1193.67Harangi, 200360. m/0.32 mm/1. μm, He
CapillarySE-30160.1193.0Santiuste, Harangi, et al., 2003 
CapillaryHP-5120.1189.6Santiuste, Harangi, et al., 2003 
CapillaryHP-5120.1199.7Santiuste J.M. and Takacs J.M., 200360. m/0.25 mm/0.25 μm, N2
CapillaryHP-5140.1211.1Santiuste J.M. and Takacs J.M., 200360. m/0.25 mm/0.25 μm, N2
CapillaryDB-5110.1189.56Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillaryDB-570.1164.56Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillaryDB-590.1176.18Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillarySE-30160.1177.Evans and Haken, 1989Column length: 25. m; Column diameter: 0.32 mm
CapillarySE-30160.1193.Tarjan, Nyiredy, et al., 1989 
CapillarySE-30120.1177.Haken and Korhonene, 1983N2; Column length: 25. m; Column diameter: 0.22 mm
CapillarySE-30140.1183.Haken and Korhonene, 1983N2; Column length: 25. m; Column diameter: 0.22 mm
CapillarySE-30160.1193.Haken and Korhonene, 1983N2; Column length: 25. m; Column diameter: 0.22 mm
PackedSE-30100.1186.Winskowski, 1983Gaschrom Q; Column length: 2. m
PackedSE-30150.1177.Winskowski, 1983Gaschrom Q; Column length: 2. m
PackedSE-30150.1161.Vylegzhanina and Keiser, 1976Chromaton N-AW-GMDS; Column length: 1. m
PackedSE-30160.1166.Vylegzhanina and Keiser, 1976Chromaton N-AW-GMDS; Column length: 1. m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryZB-Wax120.1665.5Pérez-Parajón, Santiuste, et al., 200460. m/0.25 mm/0.25 μm
CapillaryZB-Wax140.1688.6Pérez-Parajón, Santiuste, et al., 200460. m/0.25 mm/0.25 μm
CapillaryCarbowax 20M160.1630.Evans and Haken, 1989Column length: 22. m; Column diameter: 0.3 mm
CapillaryCarbowax 20M140.1630.Haken and Korhonene, 1983N2; Column length: 22. m; Column diameter: 0.3 mm
CapillaryCarbowax 20M160.1653.Haken and Korhonene, 1983N2; Column length: 22. m; Column diameter: 0.3 mm
CapillaryCarbowax 20M180.1698.Haken and Korhonene, 1983N2; Column length: 22. m; Column diameter: 0.3 mm

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51192.67Harangi, 200360. m/0.32 mm/1. μm, He, 60. C @ 2.8 min, 3. K/min; Tend: 180. C
CapillaryDB-51193.06Harangi, 200360. m/0.32 mm/1. μm, He, 60. C @ 2.8 min, 3. K/min; Tend: 180. C
CapillaryDB-51196.72Harangi, 200360. m/0.32 mm/1. μm, He, 60. C @ 2.8 min, 4. K/min; Tend: 180. C
CapillaryDB-51196.78Harangi, 200360. m/0.32 mm/1. μm, He, 60. C @ 2.8 min, 4. K/min; Tend: 180. C
CapillaryDB-11141.6Sun and Stremple, 200330. m/0.25 mm/0.25 μm, He, 3. K/min; Tstart: 40. C; Tend: 325. C
CapillaryOV-11158.5Gautzsch and Zinn, 19968. K/min; Tstart: 35. C; Tend: 300. C
CapillaryDB-51160.14Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-51166.23Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-51171.69Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-11168.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 100. C @ 0. min, 10. K/min
CapillaryDB-11162.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 100. C @ 0. min, 5. K/min
CapillaryDB-11157.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 50. C @ 0. min, 10. K/min
CapillaryDB-11150.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 50. C @ 0. min, 5. K/min
CapillaryPetrocol DH1152.White, Hackett, et al., 1992100. m/0.25 mm/0.5 μm, He, 1. K/min; Tstart: 30. C; Tend: 220. C

Van Den Dool and Kratz RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
Capillary5 % Phenyl methyl siloxane1172.Yasuhara, Shiraishi, et al., 199725. m/0.31 mm/0.52 μm, He; Program: 50C(2min) => (20C/min) => 120C => (7C/min) => 310C(10min)
PackedSE-301160.Peng, Ding, et al., 1988Supelcoport; Chromosorb; Column length: 3.05 m; Program: 40C(5min) => 10C/min => 200C or 250C (60min)

Van Den Dool and Kratz RI, polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-Wax1671.43Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 10. K/min; Tstart: 100. C
CapillaryDB-Wax1659.76Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 5. K/min; Tstart: 100. C
CapillaryDB-Wax1658.54Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 10. K/min; Tstart: 50. C
CapillaryDB-Wax1643.59Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 5. K/min; Tstart: 50. C

Normal alkane RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedDC-400150.1198.Anderson, 1968Helium, Gas-Pak (60-80 mesh); Column length: 3.0 m

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-1011142.Messadi and Ali-Mokhnache, 19932. K/min; Column length: 25. m; Column diameter: 0.20 mm; Tstart: 80. C
CapillaryOV-1011144.Messadi and Ali-Mokhnache, 19932. K/min; Column length: 25. m; Column diameter: 0.20 mm; Tstart: 80. C
CapillaryOV-1011145.Messadi and Ali-Mokhnache, 19932. K/min; Column length: 25. m; Column diameter: 0.20 mm; Tstart: 80. C
CapillaryUltra-11149.Okumura, 199125. m/0.32 mm/0.25 μm, He, 3. K/min; Tstart: 80. C; Tend: 260. C
CapillarySE-541170.Harland, Cumming, et al., 1986He, 50. C @ 2. min, 8. K/min, 250. C @ 12. min; Column length: 25. m; Column diameter: 0.32 mm

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone1177.Yu and Zazhi, 2005Program: not specified
CapillaryCP Sil 21174.Fuhrer, Deissler, et al., 199755. m/0.25 mm/0.25 μm, N2; Program: 40C(3min) => 20C/min => 80C => 2C/min => 240C(45min)
CapillaryPolydimethyl siloxanes1158.Zenkevich and Chupalov, 1996Program: not specified
CapillarySPB-11145.Vezzani, Moretti, et al., 1994Column length: 30. m; Column diameter: 0.32 mm; Program: not specified
CapillaryOV-11150.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1150.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified
CapillaryOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.1154.Waggott and Davies, 1984Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP5-MS199.Vrana, Paschke, et al., 200530. m/0.25 mm/0.25 μm, Helium, 50. C @ 5. min, 5. K/min, 280. C @ 10. min
CapillaryDB-5198.2Donnelly, Abdel-Hamid, et al., 199330. m/0.32 mm/0.25 μm, He, 40. C @ 3. min, 8. K/min, 285. C @ 29.5 min

References

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Yan, Gu, et al., 1987
Yan, H.; Gu, J.; An, X.; Hu, R., Standard enthalpies of formation and enthlpies of isomerization of trichlorobenzenes, Huaxue Xuebao, 1987, 45, 1184-1187. [all data]

Platonov and Simulin, 1985
Platonov, V.A.; Simulin, Yu.N., Determination of the standard enthalpies of formation of polychlorobenzenes. III. The standard enthalpies of formation of mono-1,2,4- and 1,3,5-tri-, and 1,2,3,4- and 1,2,3,5-tetrachlorobenzenes, Russ. J. Phys. Chem. (Engl. Transl.), 1985, 59, 179-181. [all data]

Wilhelm, Lainez, et al., 1986
Wilhelm, E.; Lainez, A.; Roux, A.H.; Grolier, J.-P.E., Excess-molar volumes and heat capacities of (1,2,4-trichlorobenzene + an n-alkane) and (1-chloronaphthalene + an n-alkane), Thermochim. Acta, 1986, 105, 101-110. [all data]

Wilhelm, Inglese, et al., 1982
Wilhelm, E.; Inglese, A.; Quint, J.R.; Grolier, J.-P.E., Molar excess volumes and excess heat capacities of (1,2,4-trichlorobenzene + an alkane), J. Chem. Thermodynam., 1982, 14, 303-308. [all data]

Petit and TerMinassian, 1974
Petit, J.C.; TerMinassian, L., Measurements of (dV/dT)p, (dV/dP)T, and (dH/dT)p by flux calorimetry, J. Chem. Thermodynam., 1974, 6, 1139-1152. [all data]

Jondorf and Williams, 1958
Jondorf, W.R.; Williams, R.T., Biochem. J., 1958, 69, 181. [all data]

Harangi, 2003
Harangi, J., Short communication. Retention index calculation without n-alkanes -- the virtual carbon number, J. Chromatogr. A, 2003, 993, 1-2, 187-195, https://doi.org/10.1016/S0021-9673(03)00320-0 . [all data]

Santiuste, Harangi, et al., 2003
Santiuste, J.M.; Harangi, J.; Takács, J.M., Mosaic increments for predicting the gas chromatographic retention data of the chlorobenzenes, J. Chromatogr. A, 2003, 1002, 1-2, 155-168, https://doi.org/10.1016/S0021-9673(03)00736-2 . [all data]

Santiuste J.M. and Takacs J.M., 2003
Santiuste J.M.; Takacs J.M., Relationships between retention data of benzene and chlorobenzenes with their physico-chemical properties and topological indices, Chromatographia, 2003, 58, 87-96. [all data]

Gerbino, Garbarino, et al., 1996
Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 1996, 86, 63-75. [all data]

Evans and Haken, 1989
Evans, M.B.; Haken, J.K., Dispersion and selectivity indices in gas chromatography. IV. Chlorinated aromatic compounds, J. Chromatogr., 1989, 468, 373-382, https://doi.org/10.1016/S0021-9673(00)96332-5 . [all data]

Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8 . [all data]

Haken and Korhonene, 1983
Haken, J.K.; Korhonene, I.O.O., Retention increments of isomeric chlorobenzenes, J. Chromatogr., 1983, 265, 323-327, https://doi.org/10.1016/S0021-9673(01)96727-5 . [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Vylegzhanina and Keiser, 1976
Vylegzhanina, G.F.; Keiser, L.S., Determination of the heats of solution of the insecticide gardona and its metabolites in the stationary phase and their Kovats retention indices, Zh. Anal. Khim., 1976, 31, 1, 171-173. [all data]

Pérez-Parajón, Santiuste, et al., 2004
Pérez-Parajón, J.M.; Santiuste, J.M.; Takács, J.M., Sensitivity of the methylbenzenes and chlorobenzenes retention index to column temperature, stationary phase polarity, and number and chemical nature of substituents, J. Chromatogr. A, 2004, 1048, 2, 223-232, https://doi.org/10.1016/j.chroma.2004.07.028 . [all data]

Sun and Stremple, 2003
Sun, G.; Stremple, P., Retention index characterization of flavor, fragrance, and many other compounds on DB-1 and DB-XLB, 2003, retrieved from http://www.chem.agilent.com/cag/cabu/pdf/b-0279.pdf. [all data]

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

Gerbino and Castello, 1995
Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 1995, 699, 1-2, 161-171, https://doi.org/10.1016/0021-9673(95)00024-H . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Yasuhara, Shiraishi, et al., 1997
Yasuhara, A.; Shiraishi, H.; Nishikawa, M.; Yamamoto, T.; Uehiro, T.; Nakasugi, O.; Okumura, T.; Kenmotsu, K.; Fukui, H.; Nagase, M.; Ono, Y.; Kawagoshi, Y.; Baba, K.; Noma, Y., Determination of organic components in leachates from hazardous waste disposal sites in Japan by gas chromatography-mass spectrometry, J. Chromatogr. A, 1997, 774, 1-2, 321-332, https://doi.org/10.1016/S0021-9673(97)00078-2 . [all data]

Peng, Ding, et al., 1988
Peng, C.T.; Ding, S.F.; Hua, R.L.; Yang, Z.C., Prediction of Retention Indexes I. Structure-Retention Index Relationship on Apolar Columns, J. Chromatogr., 1988, 436, 137-172, https://doi.org/10.1016/S0021-9673(00)94575-8 . [all data]

Anderson, 1968
Anderson, D.G., USe of Kovats retention indices and response factors for the qualitative and quantitative analysis of coating solvents, J. Paint Technol., 1968, 40, 527, 549-557. [all data]

Messadi and Ali-Mokhnache, 1993
Messadi, D.; Ali-Mokhnache, S., Calculation of retention indices and peak widths in temperature programmed gas-liquid chromatography, Chromatographia, 1993, 37, 5/6, 264-270, https://doi.org/10.1007/BF02278631 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]

Harland, Cumming, et al., 1986
Harland, B.J.; Cumming, R.I.; Gillings, E., The Kovats indexes of some organic micropollutants on an SE54 capillary column, EUR, I Org. Micropollut. Aquat. Environ., 1986, EUR 10388, 123-127. [all data]

Yu and Zazhi, 2005
Yu, H.; Zazhi, J., Relationship between chromatogram retention index and toxicity of chlorinated phenols and chlorinated benzenes to Guppy, J. Enviropn. Health (Chinese), 2005, 22, 6, 441-444. [all data]

Fuhrer, Deissler, et al., 1997
Fuhrer, U.; Deissler, A.; Schreitmuller, J.; Ballschmiter, K., Analysis of Halogenated Methoxybenzenes and Hexachlorobenzene (HCB) in the Picogram m-3 Range in Marine Air, Chromatographia, 1997, 45, 1, 414-427, https://doi.org/10.1007/BF02505594 . [all data]

Zenkevich and Chupalov, 1996
Zenkevich, I.G.; Chupalov, A.A., New Possibilities of Chromato Mass Pectrometric Identification of Organic Compounds Using Increments of Gas Chromatographic Retention Indices of Molecular Structural Fragments, Zh. Org. Khim. (Rus.), 1996, 32, 5, 656-666. [all data]

Vezzani, Moretti, et al., 1994
Vezzani, S.; Moretti, P.; Castello, G., Fast and Accurate Method for the Automatic Prediction of Programmed-Temperature Retention Times, J. Chromatogr. A, 1994, 677, 2, 331-343, https://doi.org/10.1016/0021-9673(94)80161-4 . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]

Vrana, Paschke, et al., 2005
Vrana, B.; Paschke, H.; Paschke, A.; Popp, P.; Schuurmann, G., Performance of semipermeable membrane devices for sampling of organic contaminants in groun water, J. Envirom. Monit., 2005, 7, 5, 500-508, https://doi.org/10.1039/b411645c . [all data]

Donnelly, Abdel-Hamid, et al., 1993
Donnelly, J.R.; Abdel-Hamid, M.S.; Jeter, J.L.; Gurka, D.F., Application of gas chromatographic retention properties to the identification of environmental contaminants, J. Chromatogr., 1993, 642, 1-2, 409-415, https://doi.org/10.1016/0021-9673(93)80106-I . [all data]


Notes

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), UV/Visible spectrum, Gas Chromatography, References