Anthracene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1HP-101SPB-5C103H208C103H208
Column length (m) 30.25.30.  
Carrier gas NitrogenHeHeliumH2H2
Substrate      
Column diameter (mm) 0.250.20.25  
Phase thickness (μm)  0.20.250.250.25
Tstart (C) 60.70.60.80.100.
Tend (C) 290.200.250.275.275.
Heat rate (K/min) 4.3.4.5.4.
Initial hold (min)  2.2.  
Final hold (min)  15.20.  
I 1759.1763.1775.1817.1812.
ReferenceAsif and Fazeelat, 2006Mastelic, Jerkovic, et al., 2006Pino, Marbot, et al., 2002Dumitrescu, Buda, et al., 2000Dumitrescu, Buda, et al., 2000
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-5HP-5HP-5HP-5
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm) 0.250.250.250.250.25
Tstart (C) 50.50.50.50.50.
Tend (C) 310.310.310.310.310.
Heat rate (K/min) 5.5.5.5.5.
Initial hold (min) 2.2.2.2.2.
Final hold (min)      
I 1785.1786.1788.1789.1790.
ReferenceMiao and Wu, 1999Miao and Wu, 1999Miao and Wu, 1999Miao and Wu, 1999Miao and Wu, 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-5HP-5Ultra-1PB-1
Column length (m) 30.30.30.50.50.
Carrier gas    H2H2
Substrate      
Column diameter (mm) 0.320.320.320.20.32
Phase thickness (μm) 0.250.250.250.330.2
Tstart (C) 50.50.50.60.80.
Tend (C) 310.310.310.300.270.
Heat rate (K/min) 5.5.5.3.4.
Initial hold (min) 2.2.2. 2.
Final hold (min)    35.5.
I 1791.1801.1802.1762.1754.
ReferenceMiao and Wu, 1999Miao and Wu, 1999Miao and Wu, 1999Elizalde-González, Hutfliess, et al., 1996Andersson and Weis, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5Ultra-1SE-30SE-30SE-54
Column length (m) 30.25.60.25.25.
Carrier gas H2HeN2HeHe
Substrate      
Column diameter (mm) 0.320.320.320.210.32
Phase thickness (μm) 0.250.25   
Tstart (C) 80.80.50.40.50.
Tend (C) 270.260.275.280.250.
Heat rate (K/min) 4.3.5.6.8.
Initial hold (min) 2. 8. 2.
Final hold (min) 5. 10. 12.
I 1753.1725.1743.1723.1777.
ReferenceAndersson and Weis, 1994Okumura, 1991Ibrahim and Suffet, 1988Pozhidaev, Berezkin, et al., 1987Harland, Cumming, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Asif and Fazeelat, 2006
Asif, M.; Fazeelat, T., Characterization of aromatic hydrocarbons in Dhurnal oil from Northen Indus Basin, J. Chem. Soc. Pakistan, 2006, 28, 2, 169-175. [all data]

Mastelic, Jerkovic, et al., 2006
Mastelic, J.; Jerkovic, I.; Mesic, M., Volatile constituents from flowers, leaves, bark and wood of Prunus mahaleb L., Flavour Fragr. J., 2006, 21, 2, 306-313, https://doi.org/10.1002/ffj.1596 . [all data]

Pino, Marbot, et al., 2002
Pino, J.A.; Marbot, R.; Vazquez, C., Characterization of volatiles in Loquat fruit (Eriobotrya japonica Lindl.), Revista CENIC Ciencias Quimicas, 2002, 33, 3, 115-119. [all data]

Dumitrescu, Buda, et al., 2000
Dumitrescu, V.; Buda, W.; Medvedovici, A., Evaluation of new stationary phases for capillary gas chromatography, Rev. Roum. Chim., 2000, 45, 4, 313-318. [all data]

Miao and Wu, 1999
Miao, X.; Wu, F., Study on retention behaviors of polycyclic aromatic hydrocarbons by gas chromatography in different operation models, J. Instrumental Anal., 1999, 15, 4, 288-292. [all data]

Elizalde-González, Hutfliess, et al., 1996
Elizalde-González, M.P.; Hutfliess, M.; Hedden, K., Retention index system, adsorption characteristics, and sructure correlations of polycyclic aromatic hydrocarbons in fuels, J. Hi. Res. Chromatogr., 1996, 19, 6, 345-352, https://doi.org/10.1002/jhrc.1240190608 . [all data]

Andersson and Weis, 1994
Andersson, J.T.; Weis, U., Gas Chromatographic Determination of Polycyclic Aromatic Compounds with Fluorinated Analogues as Internal Standards, J. Chromatogr. A, 1994, 659, 1, 151-161, https://doi.org/10.1016/0021-9673(94)85017-8 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]

Ibrahim and Suffet, 1988
Ibrahim, E.A.; Suffet, I.H., Freon FC-113, an Alternative to Methylene Chloride for Liquid-Liquid Extraction of Trace Organics from Chlorinated Drinking Water, J. Chromatogr., 1988, 454, 217-232, https://doi.org/10.1016/S0021-9673(00)88615-X . [all data]

Pozhidaev, Berezkin, et al., 1987
Pozhidaev, V.M.; Berezkin, V.G.; Korolev, A.A.; Popova, T.P.; Pozhideava, Capillary chromatography of polycyclic aromatic hydrocarbons on a home-produced capillary column with immobilized stationary liquid phase SE-30, Zh. Anal. Khim., 1987, 62, 12, 2222-2226. [all data]

Harland, Cumming, et al., 1986
Harland, B.J.; Cumming, R.I.; Gillings, E., The Kovats indexes of some organic micropollutants on an SE54 capillary column, EUR, I Org. Micropollut. Aquat. Environ., 1986, EUR 10388, 123-127. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References