Anthracene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-5OV-1OV-1
Column length (m) 30.30.30.25.25.
Carrier gas HeHeHe  
Substrate      
Column diameter (mm) 0.250.250.250.20.2
Phase thickness (μm) 0.250.250.250.330.33
Tstart (C) 40.40.40.100.100.
Tend (C) 310.310.310.180.180.
Heat rate (K/min) 2.4.6.5.5.
Initial hold (min)      
Final hold (min)      
I 1767.01786.41800.01780.11800.1
ReferenceSong, Lai, et al., 2003Song, Lai, et al., 2003Song, Lai, et al., 2003Zhang, Shen, et al., 2000Zhang, Shen, et al., 2000
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1DB-5DB-5DB-5SP-2100
Column length (m)  30.30.30. 
Carrier gas  HeHeHeH2
Substrate      
Column diameter (mm)  0.250.250.25 
Phase thickness (μm)  0.250.250.25 
Tstart (C) 35.40.40.40.170.
Tend (C) 300.310.310.310. 
Heat rate (K/min) 8.2.4.6.2.
Initial hold (min)      
Final hold (min)      
I 1770.91767.1786.41800.1759.49
ReferenceGautzsch and Zinn, 1996Lai and Song, 1995Lai and Song, 1995Lai and Song, 1995Podmaniczky, Szepesy, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SP-2100SP-2100SP-2100SP-2100SP-2100
Column length (m)      
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 170.170.170.170.170.
Tend (C)      
Heat rate (K/min) 4.6.2.4.6.
Initial hold (min)      
Final hold (min)      
I 1764.271770.931781.681779.871791.49
ReferencePodmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986Podmaniczky, Szepesy, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CP Sil 5 CBDB-5OV-1OV-1OV-1
Column length (m)  30.50.25.24.
Carrier gas H2He   
Substrate      
Column diameter (mm)  0.260.20.310.3
Phase thickness (μm)  0.25  1.1
Tstart (C) 170.50.35.35.35.
Tend (C)  300.280.280.250.
Heat rate (K/min) 4.6.  4.
Initial hold (min)  4.5.5.5.
Final hold (min)  20.   
I 1782.281806.1751.951757.741758.
ReferencePodmaniczky, Szepesy, et al., 1986Rostad and Pereira, 1986Knoppel, de Bortoli, et al., 1983Knoppel, de Bortoli, et al., 1983Knoppel, de Bortoli, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1SE-52SE-52SE-52SE-52
Column length (m) 30.33.316.616.616.6
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm) 0.30.500.500.500.50
Phase thickness (μm) 1.1    
Tstart (C) 35.50.50.50.50.
Tend (C) 250.320.320.320.320.
Heat rate (K/min) 4.6.6.6.6.
Initial hold (min) 5.5.5.5.5.
Final hold (min)      
I 1757.981752.1740.1749.1749.
ReferenceKnoppel, de Bortoli, et al., 1982Beernaert, 1979Beernaert, 1979Beernaert, 1979Beernaert, 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-52SE-52SE-52SE-52SE-52
Column length (m) 16.616.616.616.616.6
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.500.500.500.500.50
Phase thickness (μm)      
Tstart (C) 50.50.50.50.50.
Tend (C) 320.320.320.320.320.
Heat rate (K/min) 6.6.6.6.6.
Initial hold (min) 5.5.5.5.5.
Final hold (min)      
I 1749.1749.1750.1762.1762.
ReferenceBeernaert, 1979Beernaert, 1979Beernaert, 1979Beernaert, 1979Beernaert, 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-52SE-52SE-52SE-52SE-52
Column length (m) 16.616.616.616.616.6
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.500.500.500.500.50
Phase thickness (μm)      
Tstart (C) 50.50.50.50.50.
Tend (C) 320.320.320.320.320.
Heat rate (K/min) 6.6.6.6.6.
Initial hold (min) 5.5.5.5.5.
Final hold (min)      
I 1762.1762.1764.1765.1766.
ReferenceBeernaert, 1979Beernaert, 1979Beernaert, 1979Beernaert, 1979Beernaert, 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-52SE-52SE-52SE-52SE-52
Column length (m) 16.616.616.612.12.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.500.500.500.30.28
Phase thickness (μm)    0.340.17
Tstart (C) 50.50.50.50.50.
Tend (C) 320.320.320.250.250.
Heat rate (K/min) 6.6.6.2.2.
Initial hold (min) 5.5.5.  
Final hold (min)      
I 1770.1773.1778.1754.21744.4
ReferenceBeernaert, 1979Beernaert, 1979Beernaert, 1979Lee, Vassilaros, et al., 1979Lee, Vassilaros, et al., 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase SE-52
Column length (m) 65.
Carrier gas N2
Substrate  
Column diameter (mm) 0.3
Phase thickness (μm)  
Tstart (C) 100.
Tend (C) 300.
Heat rate (K/min) 1.8
Initial hold (min)  
Final hold (min)  
I 1750.
ReferenceCarugno and Rossi, 1967
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Song, Lai, et al., 2003
Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s)., Kluwer Academic/Plenum Publishers, New York, 2003, 147-193. [all data]

Zhang, Shen, et al., 2000
Zhang, M.-J.; Shen, S.-D.; Chen, S.-Y.; Sun, Y.-H., Analysis of heavy oil fractions in high-temperature coal tar by capillary gas chromatography/fourier transform infrared spectrometry, Chin. J. Chromatogr., 2000, 18, 3, 241-246. [all data]

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

Lai and Song, 1995
Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 1995, 74, 10, 1436-1451, https://doi.org/10.1016/0016-2361(95)00108-H . [all data]

Podmaniczky, Szepesy, et al., 1986
Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Determination of Retention Indices in LPTGC, Chromatographia, 1986, 21, 7, 387-391, https://doi.org/10.1007/BF02346137 . [all data]

Rostad and Pereira, 1986
Rostad, C.E.; Pereira, W.E., Kovats and Lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 6, 328-334, https://doi.org/10.1002/jhrc.1240090603 . [all data]

Knoppel, de Bortoli, et al., 1983
Knoppel, H.; de Bortoli, M.; Peil, A.; Vissers, H., Reproducibility of Temperature-Programmed Gas Chromatographic Retention Indices with Non-Polar Glass Capillary Columns, J. Chromatogr., 1983, 279, 483-492, https://doi.org/10.1016/S0021-9673(01)93649-0 . [all data]

Knoppel, de Bortoli, et al., 1982
Knoppel, H.; de Bortoli, M.; Peil, A.; Schauenburg, H.; Vissers, H., The determination of linear PTGC retention indices for use in environmental organics analysis, Comm. Eur. Communities, Rep. EUR, 1982, 99-109. [all data]

Beernaert, 1979
Beernaert, H., Gas Chromatographic Analysis of Polyclylic Aromatic Hydrocarbons, J. Chromatogr., 1979, 173, 1, 109-118, https://doi.org/10.1016/S0021-9673(01)80450-7 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]

Carugno and Rossi, 1967
Carugno, N.; Rossi, S., Evaluation of polynuclear hydrocarbons in cigarette smoke by glass capillary columns, J. Gas Chromatogr., 1967, 5, 2, 103-106, https://doi.org/10.1093/chromsci/5.2.103 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References