Anthracene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Lee's RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-5HP-5MSHP-5MS
Column length (m) 60.60.60.30.30.
Carrier gas    HeHe
Substrate      
Column diameter (mm)    0.250.25
Phase thickness (μm)    0.250.25
Program not specifiednot specifiednot specified60C(2min) => 6C/min => 258C => 2C/min => 300C(4min)not specified
I 301.5318.5319.5301.53301.38
ReferenceFuentes, Font, et al., 2007Fuentes, Font, et al., 2007Fuentes, Font, et al., 2007Wang, Li, et al., 2007Wang, Li, et al., 2007, 2
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5MS5 % Phenyl methyl siloxaneDB-5MSHP-5MSLM-5
Column length (m) 30. 60.30.30.
Carrier gas He  HeHe
Substrate      
Column diameter (mm) 0.25 0.250.300.25
Phase thickness (μm) 0.25  0.250.25
Program not specified70 0C (2 min) 30 0C/min -> 150 0C 5 0C/min -> 200 0C 4 0C/min -> 310 0C (5 min)not specified50 0C (2 min) 8 0C/min -> 120 0C (3 min) 10 0C/min -> 230 0C60C(2min) => 15C/min => 180C => 5C/min => 280C (10min)
I 301.53301.20301.4303.03301.37
ReferenceWang, Li, et al., 2007, 2Skrbic and Onjia, 2006Aracil, Font, et al., 2005Cheng, Liu, et al., 2005Ré-Poppi and Santiago-Silva, 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase LM-5Ultra-1Ultra-1Ultra-1Ultra-1
Column length (m) 30.50.50.50.50.
Carrier gas HeNitrogenNitrogenNitrogenNitrogen
Substrate      
Column diameter (mm) 0.250.320.320.320.32
Phase thickness (μm) 0.250.500.500.500.50
Program 60C(2min) => 15C/min => 180C => 5C/min => 280C (10min)40-100 0C 3-15 0C/min -> 290 0C40-100 0C 3-15 0C/min -> 290 0C40-100 0C 3-15 0C/min -> 290 0C40-100 0C 3-15 0C/min -> 290 0C
I 301.39301.2301.4301.5301.7
ReferenceRé-Poppi and Santiago-Silva, 2005Sremac, Skrbic, et al., 2005Sremac, Skrbic, et al., 2005Sremac, Skrbic, et al., 2005Sremac, Skrbic, et al., 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5LM-5LM-5SE-52DB-5
Column length (m) 30.30.30.30.30.
Carrier gas  HeHe He
Substrate      
Column diameter (mm) 0.250.250.250.300.25
Phase thickness (μm) 0.250.250.25 0.25
Program not specified60C(2min) => 15C/min => 180C => 5C/min => 280C(5min)60C(2min) => 15C/min => 180C => 5C/min => 280C(5min)not specified90C (1min) => 10C/min => 120C => 4C/min => 310C (20min)
I 301.4301.39301.39301.69301.38
ReferenceLundstedt, Haglund, et al., 2003Ré-Poppi and Santiago-Silva, 2002Ré-Poppi and Santiago-Silva, 2002Wang, Peng, et al., 1997Zamperlini, Silva, et al., 1997
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5SE-54SE-52SE-54DB-5
Column length (m) 30.30.30.  
Carrier gas He   He
Substrate      
Column diameter (mm) 0.250.250.25  
Phase thickness (μm) 0.25    
Program 90C (1min) => 10C/min => 120C => 4C/min => 310C (20min)not specifiednot specifiednot specified70C(2min) => 30C/min => 150C => 5C/min => 200C => 4C/min => 310C
I 301.7301.69301.08301.05301.17
ReferenceZamperlini, Silva, et al., 1997Chen, 1996Shaogang and Xiaobai, 1994Guillen, Iglesias, et al., 1992Takada, Onda, et al., 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-5DB-5OV-101
Column length (m) 30.30.30.30. 
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.32 
Phase thickness (μm)      
Program not specifiednot specifiednot specifiednot specifiednot specified
I 301.69301.73301.92301.92301.4
ReferenceNaikwadi, Charbonneau, et al., 1987Naikwadi, Charbonneau, et al., 1987Naikwadi, Charbonneau, et al., 1987Naikwadi, Charbonneau, et al., 1987Tucminen, Wickstrom, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5SE-52SE-52SE-52SE-52
Column length (m) 30.    
Carrier gas He    
Substrate      
Column diameter (mm) 0.25    
Phase thickness (μm)      
Program not specifiednot specifiednot specifiednot specifiednot specified
I 301.69301.29301.52301.69301.87
ReferenceTong, Centen, et al., 1985Shlyakhov, 1984Shlyakhov, 1984Shlyakhov, 1984Shlyakhov, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Lee's RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Fuentes, Font, et al., 2007
Fuentes, M.J.; Font, R.; Gomez-Rico, M.F.; Martin-Gullon, I., Pyrolysis and combustion of waste lubricant oil from diesel cars: Decomposition and pollutants, J. Anal. Appl. Pyrolysis, 2007, 79, 1-2, 215-226, https://doi.org/10.1016/j.jaap.2006.12.004 . [all data]

Wang, Li, et al., 2007
Wang, Z.; Li, K.; Lambert, P.; Yang, C., Identification, characterization and quantitation of pyrogenic polycylic aromatic hydrocarbons and other organic compounds in tire fire products, J. Chromatogr. A, 2007, 1139, 1, 14-26, https://doi.org/10.1016/j.chroma.2006.10.085 . [all data]

Wang, Li, et al., 2007, 2
Wang, Z.; Li, K.; Lambert, P.; Brown, C.E.; Yang, C.; Hollebone, B.P., Identification and characterization of polycyclic aromatic compounds in tire fire products and differentiation of pyrogenic PAHs from petrogenic PAHs in Proceedings of the 30th Arctic and Marine Oilspill (AMOP) Technical Seminar. Vol.1, 2007, 61-85. [all data]

Skrbic and Onjia, 2006
Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 2006, 1108, 2, 279-284, https://doi.org/10.1016/j.chroma.2006.01.080 . [all data]

Aracil, Font, et al., 2005
Aracil, I.; Font, R.; Conesa, J.A., Semivolatile and volatile compounds from the pyrolysis and combustion of polyvinyl chloride, J. Anal. Appl. Pyrolysis, 2005, 74, 1-2, 465-478, https://doi.org/10.1016/j.jaap.2004.09.008 . [all data]

Cheng, Liu, et al., 2005
Cheng, D.-X.; Liu, B.-X.; Sun, Y.-A.; Xie, B.; Zhang, H.-L., rapid analysis of pyrolysis products of cholesterol by GC-MS assited with boiling point - Lee retention index, journal of Instrumental Analysis - Fenxi ceshi xuebao, 2005, 24, 6, 85-88. [all data]

Ré-Poppi and Santiago-Silva, 2005
Ré-Poppi, N.; Santiago-Silva, M., Polycyclic aromatic hydrocarbons and other selected organic compounds in ambient air of Campo Grande City, Brazil, Atmos. Environ., 2005, 39, 16, 2839-2850, https://doi.org/10.1016/j.atmosenv.2004.10.006 . [all data]

Sremac, Skrbic, et al., 2005
Sremac, S.; Skrbic, B.; Onjia, A., Artificial neural network prediction of quantitative structure-retention relationships of polycyclic aromatic hydrocarbons in gas chromatography, J. Serb. Chem. Soc., 2005, 70, 11, 1291-1300, https://doi.org/10.2298/JSC0511291S . [all data]

Lundstedt, Haglund, et al., 2003
Lundstedt, S.; Haglund, P.; Öberg, L., Degradation and formation of polycyclic aromatic compounds during bioslurry treatment of an aged gasworks soil, Environ. Toxicol. Chem., 2003, 22, 7, 1413-1420, https://doi.org/10.1002/etc.5620220701 . [all data]

Ré-Poppi and Santiago-Silva, 2002
Ré-Poppi, N.; Santiago-Silva, M.R., Identification of polycyclic aromatic hydrocarbons and methoxylated phenols in wood smoke emitted during production of charcoal, Chromatographia, 2002, 55, 7/8, 475-481, https://doi.org/10.1007/BF02492280 . [all data]

Wang, Peng, et al., 1997
Wang, Y.; Peng, P.; Cui, S.; Zhang, Y., Identification of PAH in the Suzhou River bed sediments by GC/MS and PAH retention index system, J. Nanjing Norm. Univ. (Nat. Sci.), 1997, 20, 2, 47-68. [all data]

Zamperlini, Silva, et al., 1997
Zamperlini, G.C.M.; Silva, M.R.S.; Vilegas, W., Identification of polycyclic aromatic hydrocarbons in sugar cane soot by gas chromatography-mass spectrometry, Chromatographia, 1997, 46, 11/12, 655-663, https://doi.org/10.1007/BF02490527 . [all data]

Chen, 1996
Chen, J., GC and GC/MS methods for the analysis of polycyclic aromatic hydrocarbon (PAH) in sediment of the grand canal of China, Toxicol. Environ. Chem., 1996, 54, 1-4, 69-73, https://doi.org/10.1080/02772249609358297 . [all data]

Shaogang and Xiaobai, 1994
Shaogang, C.; Xiaobai, X., System for calculating the linear temperature-programmed retention indices of polycylic aromatic compounds, J. Hi. Res. Chromatogr., 1994, 17, 5, 339-342, https://doi.org/10.1002/jhrc.1240170511 . [all data]

Guillen, Iglesias, et al., 1992
Guillen, M.D.; Iglesias, M.J.; Dominguez, A.; Blanco, C.G., Polynuclear aromatic hydrocarbon retention indices on SE-54 stationary phase of the volatile components of a coal tar pitch. Relationships between chromatographic retention and thermal reactivity, J. Chromatogr., 1992, 591, 1-2, 287-295, https://doi.org/10.1016/0021-9673(92)80246-Q . [all data]

Takada, Onda, et al., 1990
Takada, H.; Onda, T.; Ogura, N., Determination of polycyclic aromatic hydrocarbons in urban street dusts and their source materials by capillary gas chromatography, Environ. Sci. Technol., 1990, 24, 8, 1179-1186, https://doi.org/10.1021/es00078a005 . [all data]

Naikwadi, Charbonneau, et al., 1987
Naikwadi, K.P.; Charbonneau, G.M.; Karasek, F.W.; Clement, R.E., Separation and Identification of Organic Compounds in Air Particulate Extracts by High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectrometry, J. Chromatogr., 1987, 398, 227-237, https://doi.org/10.1016/S0021-9673(01)96508-2 . [all data]

Tucminen, Wickstrom, et al., 1986
Tucminen, A.; Wickstrom, K.; Pyysalo, H., Determination of Polycyclic Aromatic Compounds by GLC-Selected Ion Monitoring (SIM) Technique, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 8, 469-471, https://doi.org/10.1002/jhrc.1240090813 . [all data]

Tong, Centen, et al., 1985
Tong, H.Y.; Centen, J.D.; Karasek, F.W.; Jellum, E.; Helland, P., Identification of Trace Organic Compounds in Dimethyl Sulphoxide Solution Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectrometry, J. Chromatogr., 1985, 324, 373-383, https://doi.org/10.1016/S0021-9673(01)81336-4 . [all data]

Shlyakhov, 1984
Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221. [all data]


Notes

Go To: Top, Lee's RI, non-polar column, custom temperature program, References