Naphthalene, 1,2,3,4-tetrahydro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5 MSPolydimethyl siloxane with 5 % Ph groupsPolydimethyl siloxane with 5 % Ph groupsSqualaneHP-5
Column length (m) 30.   30.
Carrier gas Helium    
Substrate      
Column diameter (mm) 0.25   0.25
Phase thickness (μm) 0.25   0.25
Program not specifiednot specifiednot specifiednot specified40 0C (2 min) 5 0C/min -> 80 0C 7 oC/min -> 160 0C 9 0C/min -> 200 0C 20 0C/min -> 280 0C (10 min)
I 1158.1171.1179.1137.1162.
ReferenceKotowska, Zalikowski, et al., 2012Robinson, Adams, et al., 2012Robinson, Adams, et al., 2012Chen, 2008Zhao, Li, et al., 2008
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5Polymethylsiloxane, (PMS-20000)HP Ultra 1DB-1OV-1
Column length (m) 30. 25.30.60.
Carrier gas   Nitrogen  
Substrate      
Column diameter (mm) 0.25 0.200.530.32
Phase thickness (μm) 0.25 0.331.5 
Program not specifiednot specified50 0C 4 0C/min -> 180 0C 10 0C/min -> 280 0C40 0C (4 min) 8 0C/min -> 200 0C (1 min) 5 0C/min -> 280 0C (20 min)1) 1st 30m column temp ramp 4C/min 60-120C 2)2nd 30m column isothermal 100C
I 1163.1130.1144.1169.1142.1
ReferenceZhao, Li, et al., 2008Cornwell and Cordano, 2003Hernandes, Vargas-Arispuro, et al., 1999Peng, 1996Engewald and Maurer, 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1OV-1OV-1OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.
Column length (m) 60.60.60.50.50.
Carrier gas    HydrogenHydrogen
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)      
Program 1) 1st 30m column temp ramp 4C/min 60-120C. 2) 2nd 30m column isothermal 120C.1) 1st 30m column temp ramp 6C/min 60-120C. 2) 2nd 30m column isothermal 120C.1)1st 30m column temp ramp 3C/min 60-120 2)2nd 30m column isothermal 120Cnot specifiednot specified
I 1152.91149.71152.41141.1136.
ReferenceEngewald and Maurer, 1990Engewald and Maurer, 1990Engewald and Maurer, 1990Waggott and Davies, 1984Waggott and Davies, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase Apieson L
Column length (m) 50.
Carrier gas Helium
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm)  
Program not specified
I 1153.
ReferenceVaisberg and Gizitdinova, 1969
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kotowska, Zalikowski, et al., 2012
Kotowska, U.; Zalikowski, M.; Isidorov, V.A., HS-SPME/GC-MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge, Environ. Monit. Asses., 2012, 184, 5, 2893-2907, https://doi.org/10.1007/s10661-011-2158-8 . [all data]

Robinson, Adams, et al., 2012
Robinson, A.L.; Adams, D.O.; Boss, P.K.; Heymann, H.; Solomon, P.S.; Trengove, R.D., Influence of geographic origine on the sensory characteristics and wine composition of Vitus viniferas cv. Cabernet Sauvignon wines from Australia (Supplemental data), Am. J. Enol. Vitic., 2012, 64, 4, 467-476, https://doi.org/10.5344/ajev.2012.12023 . [all data]

Chen, 2008
Chen, H.-F., Quantitative prediction of gas chromatography retention indices with support vector machines, radial basis neutral networks and multiple linear regression, Anal. Chim. Acta, 2008, 609, 1, 24-36, https://doi.org/10.1016/j.aca.2008.01.003 . [all data]

Zhao, Li, et al., 2008
Zhao, Y.; Li, J.; Xu, Y.; Duan, H.; Fan, W.; Zhao, G., EXtraction, preparation and identification of volatile compounds in Changyu XO brandy, Chinese J. Chromatogr., 2008, 26, 2, 212-222, https://doi.org/10.1016/S1872-2059(08)60014-0 . [all data]

Cornwell and Cordano, 2003
Cornwell, E.; Cordano, G., Nueva proposicion para predecir datos de retencion obtenidos mediante cromatografia de gases de hidrocarburos derivados de las naftas, Revista de la Sociedad Quimica de Mexico, 2003, 47, 1, 38-43. [all data]

Hernandes, Vargas-Arispuro, et al., 1999
Hernandes, N.N.; Vargas-Arispuro, I.; Sanz, I.; Adelantado, M.; Primo-Yufera, E., Electroantennogram activity and attraction assay of Ceratitis capitata to aiborne volatiles from peach at three ripeness stages, The Southwestern entomologist, 1999, 24, 2, 133-142. [all data]

Peng, 1996
Peng, C.T., Gas chromatographic identification of aromatic hydrocarbons in Liquid Scintillation Spectrometry, Cook, G.T.; Harkness, D.D.; MacKenzie, A.B.; Miller, B.F.; Scott, E.M., ed(s)., 1996, 221-232. [all data]

Engewald and Maurer, 1990
Engewald, W.; Maurer, T., Enhanced possibilities for identification by the use of series-coupled capillary gas chromatographic columns. I. General exposition and application of the retention index concept, J. Chromatogr., 1990, 520, 3-13, https://doi.org/10.1016/0021-9673(90)85078-A . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]

Vaisberg and Gizitdinova, 1969
Vaisberg, K.M.; Gizitdinova, V.G., Gas chromatographic investigation of tetralin and its homologues C11-C12, Neftekhimia (Rus), 1969, 9, 3, 482-486. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References