Benzene, hexachloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1OV-1OV-1OV-1OV-1
Column length (m)  25.25.25.25.
Carrier gas      
Substrate      
Column diameter (mm)  0.320.320.320.32
Phase thickness (μm)  0.100.100.100.10
Tstart (C) 35.160.160.160.160.
Tend (C) 300.240.240.240.240.
Heat rate (K/min) 8.1.1.1.31.3
Initial hold (min)  1.1.1.1.
Final hold (min)      
I 1700.01688.1691.1691.1693.
ReferenceGautzsch and Zinn, 1996de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1OV-1OV-1OV-1CP Sil 5 CB
Column length (m) 25.25.25.25.25.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.22
Phase thickness (μm) 0.100.100.100.10 
Tstart (C) 160.160.160.160.120.
Tend (C) 240.240.240.240.250.
Heat rate (K/min) 1.51.52.2.3.
Initial hold (min) 1.1.1.1.1.
Final hold (min)      
I 1688.1690.1691.1693.1662.
Referencede Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991de Paoli, Taccheo-Barbina, et al., 1991Wells, Gillespie, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

de Paoli, Taccheo-Barbina, et al., 1991
de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G., Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards, J. Chromatogr., 1991, 547, 355-365, https://doi.org/10.1016/S0021-9673(01)88659-3 . [all data]

Wells, Gillespie, et al., 1985
Wells, D.E.; Gillespie, M.J.; Porter, A.E.A., Dichlorobenzyl alkyl ether homologs as retention index markers and internal standards for the analysis of environmental samples using capillary gas chromatography, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 8, 443-449, https://doi.org/10.1002/jhrc.1240080818 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References