1-Decanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CP-WaxDB-WaxOV-351OV-351OV-351
Column length (m) 25.25.25.25.25.
Carrier gas   N2N2N2
Substrate      
Column diameter (mm) 0.250.250.320.320.32
Phase thickness (μm) 0.220.22   
Temperature (C) 240.240.100.120.140.
I 1724.1769.1746.1726.1760.
ReferenceHanai and Hong, 1989Hanai and Hong, 1989Haken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase OV-351OV-351OV-351OV-351PEG-2000
Column length (m) 25.25.25.25.3.
Carrier gas N2N2N2N2He
Substrate     Celite 545 (44-60 mesh)
Column diameter (mm) 0.320.320.320.32 
Phase thickness (μm)      
Temperature (C) 160.180.200.220.179.
I 1759.1753.1764.1783.1750.
ReferenceHaken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985Anderson, Jurel, et al., 1973
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPacked
Active phase PEG-2000Carbowax 20MCarbowax 20MCarbowax 20M
Column length (m) 3.2.552.552.
Carrier gas He   
Substrate Celite 545 (44-60 mesh)  Chromosorb W
Column diameter (mm)     
Phase thickness (μm)     
Temperature (C) 200.130.165.180.
I 1740.1732.1736.1740.
ReferenceAnderson, Jurel, et al., 1973Singliar, 1972Singliar, 1972Zarazir, Chovin, et al., 1970
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Hanai and Hong, 1989
Hanai, T.; Hong, C., Structure-retention correlation in CGC, J. Hi. Res. Chromatogr., 1989, 12, 5, 327-332, https://doi.org/10.1002/jhrc.1240120517 . [all data]

Haken and Korhonen, 1985
Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXVII. Retention increments of C1-C18 primary alkanols and their 2-chloropropanoyl and 3-chloropropanoyl derivatives on SE-30 and OV-351 capillary columns, J. Chromatogr., 1985, 319, 131-142, https://doi.org/10.1016/S0021-9673(01)90548-5 . [all data]

Anderson, Jurel, et al., 1973
Anderson, A.; Jurel, S.; Shymanska, M.; Golender, L., Gas-liquid chromatography of some aliphatic and heterocyclic mono- and pollyfunctional amines. VII. Retention indices of amines in some polar and unpolar stationary phases, Latv. PSR Zinat. Akad. Vestis Kim. Ser., 1973, 1, 51-63. [all data]

Singliar, 1972
Singliar, M., Chromatographic Behaviour and the Structure of Secondary Aliphatic Alcohols, J. Chromatogr., 1972, 65, 1, 311-321, https://doi.org/10.1016/S0021-9673(00)86946-0 . [all data]

Zarazir, Chovin, et al., 1970
Zarazir, D.; Chovin, P.; Guiochon, G., Identification of hydroxylic compounds and their derivatives by gas chromatography, Chromatographia, 1970, 3, 4, 180-195, https://doi.org/10.1007/BF02269018 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References