1-Tetradecene
- Formula: C14H28
- Molecular weight: 196.3721
- IUPAC Standard InChIKey: HFDVRLIODXPAHB-UHFFFAOYSA-N
- CAS Registry Number: 1120-36-1
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Species with the same structure:
- Other names: n-Tetradec-1-ene; α-Tetradecene; Neodene 14; Tetradec-1-ene; Tetradecene-1
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, polar column, temperature ramp
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | DB-Wax | DB-Wax | DB-Wax | DB-Wax | DB-Wax |
Column length (m) | 60. | 60. | 60. | 60. | 60. |
Carrier gas | Helium | Helium | N2 | N2 | |
Substrate | |||||
Column diameter (mm) | 0.32 | 0.32 | 0.25 | 0.25 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.25 | |
Tstart (C) | 30. | 30. | 70. | 70. | 60. |
Tend (C) | 200. | 200. | 230. | 230. | 220. |
Heat rate (K/min) | 2. | 2. | 2. | 2. | 3. |
Initial hold (min) | 4. | 4. | 2. | 2. | 4. |
Final hold (min) | 30. | 30. | 20. | 20. | |
I | 1444. | 1446. | 1429. | 1433. | 1454. |
Reference | Beck, Higbee, et al., 2008 | Beck, Higbee, et al., 2008 | Choi, 2004 | Choi, 2004, 2 | Chung, Eiserich, et al., 1993 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary |
---|---|
Active phase | DB-Wax |
Column length (m) | 60. |
Carrier gas | |
Substrate | |
Column diameter (mm) | 0.32 |
Phase thickness (μm) | |
Tstart (C) | 50. |
Tend (C) | 230. |
Heat rate (K/min) | 4. |
Initial hold (min) | |
Final hold (min) | 10. |
I | 1443. |
Reference | Binder, Turner, et al., 1990 |
Comment | MSDC-RI |
References
Go To: Top, Normal alkane RI, polar column, temperature ramp, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Beck, Higbee, et al., 2008
Beck, J.J.; Higbee, B.S.; Marrill, G.B.; Roitman, J.N.,
Comparison of volatile emissions from undamaged and mechanically damaged almonds,
J, Sci. Food Argic., 2008, 88, 8, 1363-1368, https://doi.org/10.1002/jsfa.3224
. [all data]
Choi, 2004
Choi, H.-S.,
Volatile constituents of satsuma mandarins growing in Korea,
Flavour Fragr. J., 2004, 19, 5, 406-412, https://doi.org/10.1002/ffj.1283
. [all data]
Choi, 2004, 2
Choi, H.-S.,
Aroma evaluation of an aquatic herb, changpo (Acorus calamus Var. angustatus Bess), by AEDA and SPME,
J. Agric. Food Chem., 2004, 52, 26, 8099-8104, https://doi.org/10.1021/jf040239p
. [all data]
Chung, Eiserich, et al., 1993
Chung, T.Y.; Eiserich, J.P.; Shibamoto, T.,
Volatile compounds identified in headspace samples of peanut oil heated under temperatures ranging from 50 to 200 °C,
J. Agric. Food Chem., 1993, 41, 9, 1467-1470, https://doi.org/10.1021/jf00033a022
. [all data]
Binder, Turner, et al., 1990
Binder, R.G.; Turner, C.E.; Flath, R.A.,
Comparison of yellow starthistle volatiles from different plant parts,
J. Agric. Food Chem., 1990, 38, 3, 764-767, https://doi.org/10.1021/jf00093a038
. [all data]
Notes
Go To: Top, Normal alkane RI, polar column, temperature ramp, References
- Symbols used in this document:
Tend Final temperature Tstart Initial temperature - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.