Bis(2-chloroethyl) ether

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-1OV-1SE-54Ultra-1DB-1
Column length (m) 30.15.25.25.15.
Carrier gas HeHeHe He
Substrate      
Column diameter (mm) 0.250.320.320.320.32
Phase thickness (μm) 0.250.250.250.520.25
Tstart (C) 40.50.40.35.50.
Tend (C) 325.280.280.320.300.
Heat rate (K/min) 3.10.10.15.10.
Initial hold (min)  2.1. 2.
Final hold (min)  10.10.10.5.
I 945.9948.984.951.52948.
ReferenceSun and Stremple, 2003Kostiainen, 2000Kostiainen, 2000Richmond and Pombo-Villar, 1997D'agostino and Provost, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase DB-5
Column length (m) 15.
Carrier gas  
Substrate  
Column diameter (mm) 0.32
Phase thickness (μm) 0.25
Tstart (C) 50.
Tend (C) 300.
Heat rate (K/min) 10.
Initial hold (min) 2.
Final hold (min) 5.
I 984.
ReferenceD'agostino and Provost, 1988
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Sun and Stremple, 2003
Sun, G.; Stremple, P., Retention index characterization of flavor, fragrance, and many other compounds on DB-1 and DB-XLB, 2003, retrieved from http://www.chem.agilent.com/cag/cabu/pdf/b-0279.pdf. [all data]

Kostiainen, 2000
Kostiainen, O., Gas Chromatography in Screening of Chemicals Related to the Chemical Weapons Convention in Encyclopedia of Analytical Chemistry, Meyers, R.A., ed(s)., John Wiley Sons Ltd, Chichester, 2000, 963-979. [all data]

Richmond and Pombo-Villar, 1997
Richmond, R.; Pombo-Villar, E., Short communication. Gas chromatography-mass spectrometry coupled with pseudo-Sadtler retention indices, for the identification of components in the essential oil of Curcuma longa L., J. Chromatogr. A, 1997, 760, 2, 303-308, https://doi.org/10.1016/S0021-9673(96)00802-3 . [all data]

D'agostino and Provost, 1988
D'agostino, P.A.; Provost, L.R., Gas chromatographic retention indices of sulphur vesicants and related compounds, J. Chromatogr., 1988, 436, 399-411, https://doi.org/10.1016/S0021-9673(00)94599-0 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References