NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Carbowax 20MCarbowax 20MOV-351OV-351OV-351
Column length (m) 50.50.25.25.25.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm) 0.230.230.320.320.32
Phase thickness (μm)      
Temperature (C) 80.90.100.120.140.
I 1384.1384.1357.1332.1362.
ReferenceBoneva, 1987Boneva, 1987Haken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-351OV-351OV-351Carbowax 20MCarbowax 20M
Column length (m) 25.25.25.  
Carrier gas N2N2N2  
Substrate      
Column diameter (mm) 0.320.320.32  
Phase thickness (μm)      
Temperature (C) 160.180.80.100.110.
I 1378.1358.1348.1347.991346.20
ReferenceHaken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985Podmaniczky, Szepesy, et al., 1985Podmaniczky, Szepesy, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPackedPackedPacked
Active phase Carbowax 20MCarbowax 20MCarbowax 20MPEG-2000PEG-2000
Column length (m)    3.3.
Carrier gas    HeHe
Substrate   ChromosorbCelite 545 (44-60 mesh)Celite 545 (44-60 mesh)
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 120.90.100.120.150.
I 1344.791348.981315.1329.1326.
ReferencePodmaniczky, Szepesy, et al., 1985Podmaniczky, Szepesy, et al., 1985Kevei and Kozma, 1976Anderson, Jurel, et al., 1973Anderson, Jurel, et al., 1973
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedCapillary
Active phase PEG-2000PEG-2000PEG-2000PEG-2000Carbowax 20M
Column length (m) 3.3.3.3.15.24
Carrier gas HeHeHeHeN2
Substrate Celite 545 (44-60 mesh)Celite 545 (44-60 mesh)Celite 545 (44-60 mesh)Celite 545 (44-60 mesh) 
Column diameter (mm)     0.5
Phase thickness (μm)      
Temperature (C) 152.179.180.200.130.
I 1357.1350.1321.1342.1355.
ReferenceAnderson, Jurel, et al., 1973Anderson, Jurel, et al., 1973Anderson, Jurel, et al., 1973Anderson, Jurel, et al., 1973Hedin, Thopson, et al., 1972
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Carbowax 20MCarbowax 20MPolyethylene Glycol 4000Polyethylene Glycol 4000Polyethylene Glycol 4000
Column length (m) 2.2.6.6.6.
Carrier gas      
Substrate Chromosorb WChromosorb WChromosorb PChromosorb PChromosorb P
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 100.140.100.120.140.
I 1342.1350.1338.1347.1342.
ReferenceZarazir, Chovin, et al., 1970Zarazir, Chovin, et al., 1970Bonastre and Grenier, 1968Bonastre and Grenier, 1968Bonastre and Grenier, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Boneva, 1987
Boneva, S., Gas Chromatographic Retention Indices for C6 Alkanols on OV-101 and Carbowax 20M Capillary Columns, Chromatographia, 1987, 23, 1, 50-52, https://doi.org/10.1007/BF02310419 . [all data]

Haken and Korhonen, 1985
Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXVII. Retention increments of C1-C18 primary alkanols and their 2-chloropropanoyl and 3-chloropropanoyl derivatives on SE-30 and OV-351 capillary columns, J. Chromatogr., 1985, 319, 131-142, https://doi.org/10.1016/S0021-9673(01)90548-5 . [all data]

Podmaniczky, Szepesy, et al., 1985
Podmaniczky, L.; Szepesy, L.; Lakszner, K.; Schomburg, G., Relationship between thermodynamic characteristics and isothermal retention indices, Chromatographia, 1985, 20, 10, 623-628, https://doi.org/10.1007/BF02263223 . [all data]

Kevei and Kozma, 1976
Kevei, E.; Kozma, E., Gaschromatographische Untersuchungsmethoden zur Aromaprüfung in gekochtem Schweinefleisch (M. semimembranosus), Nahrung, 1976, 20, 3, 243-252, https://doi.org/10.1002/food.19760200303 . [all data]

Anderson, Jurel, et al., 1973
Anderson, A.; Jurel, S.; Shymanska, M.; Golender, L., Gas-liquid chromatography of some aliphatic and heterocyclic mono- and pollyfunctional amines. VII. Retention indices of amines in some polar and unpolar stationary phases, Latv. PSR Zinat. Akad. Vestis Kim. Ser., 1973, 1, 51-63. [all data]

Hedin, Thopson, et al., 1972
Hedin, P.A.; Thopson, A.C.; Gueldner, R.C.; Minyard, J.P., Volatile constituents of the boll weevil, J. Insect. Physiol., 1972, 18, 1, 79-86, https://doi.org/10.1016/0022-1910(72)90066-2 . [all data]

Zarazir, Chovin, et al., 1970
Zarazir, D.; Chovin, P.; Guiochon, G., Identification of hydroxylic compounds and their derivatives by gas chromatography, Chromatographia, 1970, 3, 4, 180-195, https://doi.org/10.1007/BF02269018 . [all data]

Bonastre and Grenier, 1968
Bonastre, J.; Grenier, P., Contribution à l'étude de la polarité des phases stationnaires en chromatographie gaz-liquide. III. Calcul des coefficients d'activité relatifs et des indices de rétention de quelques alcools aliphatiques, Bull. Soc. Chim. Fr., 1968, 1, 118-125. [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References