Decanoic acid, methyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CP-WaxDB-WaxCarbowax 20MCarbowax 20MCarbowax 20M
Column length (m) 25.25.22.22.25.
Carrier gas   N2N2N2
Substrate      
Column diameter (mm) 0.250.250.30.30.25
Phase thickness (μm) 0.220.22   
Temperature (C) 240.240.120.140.110.
I 1597.1636.1624.1570.1598.3
ReferenceHanai and Hong, 1989Hanai and Hong, 1989Haken and Korhonen, 1984Haken and Korhonen, 1984Krupcik, Matisova, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Carbowax 20MCarbowax 20MCarbowax 20MCarbowax 20MCarbowax 20M
Column length (m) 25.25.25.25.25.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm)      
Temperature (C) 110.110.110.90.90.
I 1603.01605.21616.31592.51600.7
ReferenceKrupcik, Matisova, et al., 1982Krupcik, Matisova, et al., 1982Krupcik, Matisova, et al., 1982Krupcik, Matisova, et al., 1982Krupcik, Matisova, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase Carbowax 20MCarbowax 20M
Column length (m) 25.25.
Carrier gas N2N2
Substrate   
Column diameter (mm) 0.250.25
Phase thickness (μm)   
Temperature (C) 90.90.
I 1606.91613.2
ReferenceKrupcik, Matisova, et al., 1982Krupcik, Matisova, et al., 1982
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Hanai and Hong, 1989
Hanai, T.; Hong, C., Structure-retention correlation in CGC, J. Hi. Res. Chromatogr., 1989, 12, 5, 327-332, https://doi.org/10.1002/jhrc.1240120517 . [all data]

Haken and Korhonen, 1984
Haken, J.K.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXV. Capillary column studies of monochlorinated C5-C18 n-carboxylic esters, J. Chromatogr., 1984, 298, 89-100, https://doi.org/10.1016/S0021-9673(01)92697-4 . [all data]

Krupcik, Matisova, et al., 1982
Krupcik, J.; Matisova, E.; Garaj, J.; Sojak, L.; Brezkin, V.G., Contribution of adsorption to retention data in glass capillary gas chromatography. Part. I. Polar stationary phases, Chromatographia, 1982, 16, 1, 166-168, https://doi.org/10.1007/BF02258890 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References