Butane, 1-chloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxanesMethyl SiliconeMethyl SiliconeMethyl SiliconeSPB-1
Column length (m)     60.
Carrier gas     He
Substrate      
Column diameter (mm)     0.53
Phase thickness (μm)     5.
Program not specifiednot specifiednot specifiednot specified40C(6min) => 5C/min => 80C => 10C/min => 200C
I 637.637.637.637.641.
ReferenceZenkevich, 2003Zenkevich and Marinichev, 2001Zenkevich, 2001Zenkevich, 1999Flanagan, Streete, et al., 1997
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxanesSPB-1SPB-1OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.OV-1
Column length (m)  60.60.50. 
Carrier gas  HeliumHeliumHydrogen 
Substrate      
Column diameter (mm)  0.530.530.32 
Phase thickness (μm)  5.05.0  
Program not specified40 0C (6 min) 5 0C/min -> 80 0C 10 0C/min -> 200 0Cnot specifiednot specifiednot specified
I 637.641.642.635.642.
ReferenceZenkevich and Chupalov, 1996Strete, Ruprah, et al., 1992Strete, Ruprah, et al., 1992Waggott and Davies, 1984Ramsey and Flanagan, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase Apiezon LSqualane
Column length (m)   
Carrier gas   
Substrate   
Column diameter (mm)   
Phase thickness (μm)   
Program not specifiednot specified
I 648.3639.1
ReferenceKeiko, Prokop'ev, et al., 1972Keiko, Prokop'ev, et al., 1972
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zenkevich, 2003
Zenkevich, I.G., Criteria for Evaluation of Elution Order of Isomeric Organic Compounds, Zh. Phys. Khim. (Rus.), 2003, 77, 1, 92-98. [all data]

Zenkevich and Marinichev, 2001
Zenkevich, I.G.; Marinichev, A.N., Comparison of Topological and Dynamics Molecular Characteristics for Precalculation of Chromatographic Retention Parameters of Organic Compounds (in Russian), Zh. Struct. Khim., 2001, 42, 5, 893-902. [all data]

Zenkevich, 2001
Zenkevich, I.G., Interpretation of Gas Chromatographic Retention Indices in estimation of Structures of Isomeric Products of Radical Chlorinating of Alkyl Arenes, Zh. Org. Khim., 2001, 37, 2, 283-293. [all data]

Zenkevich, 1999
Zenkevich, I.G., Mutual Correlation between Gas-Chromatographic Retention Indices of Organic Compounds from Different Series, Zh. Anal. Khim., 1999, 54, 12, 1272-1279. [all data]

Flanagan, Streete, et al., 1997
Flanagan, R.J.; Streete, P.J.; Ramsey, J.D., Volatile Substance Abuse, UNODC Technical Series, No 5, United Nations, Office on Drugs and Crime, Vienna International Centre, PO Box 500, A-1400 Vienna, Austria, 1997, 56, retrieved from http://www.odccp.org/pdf/technicalseries1997-01-011.pdf. [all data]

Zenkevich and Chupalov, 1996
Zenkevich, I.G.; Chupalov, A.A., New Possibilities of Chromato Mass Pectrometric Identification of Organic Compounds Using Increments of Gas Chromatographic Retention Indices of Molecular Structural Fragments, Zh. Org. Khim. (Rus.), 1996, 32, 5, 656-666. [all data]

Strete, Ruprah, et al., 1992
Strete, P.J.; Ruprah, M.; Ramsey, J.D.; Flanagan, R.J., Detection and identification of volatile substances by headspace capillary gas chromatography to aid the diagnosis of acute poisoning, Analyst, 1992, 117, 7, 1111-1127, https://doi.org/10.1039/an9921701111 . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]

Ramsey and Flanagan, 1982
Ramsey, J.D.; Flanagan, R.J., Detection and Identification of Volatile Organic Compounds in Blood by Headspace Gas Chromatography as an Aid to the Diagnosis of Solvent Abuse, J. Chromatogr., 1982, 240, 2, 423-444, https://doi.org/10.1016/S0021-9673(00)99622-5 . [all data]

Keiko, Prokop'ev, et al., 1972
Keiko, V.V.; Prokop'ev, B.V.; Kuz'menko, L.P.; Kalinina, N.A.; Modonov, V.B., The use of an additive scheme of calculation of the indices of retention in gas-liquid chromatography communication. 3. Some regularities in the manifestation of the inductive effect, Izv. Akad. Nauk Kaz. SSR Ser. Khim., 1972, 12, 2629-2633. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References