Cyclohexanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Carbowax 20MCarbowax 20MNukolDB-WaxDB-Wax
Column length (m)   25.30. 
Carrier gas   N2He 
Substrate      
Column diameter (mm)   0.250.25 
Phase thickness (μm)    0.25 
Program not specifiednot specified45C(5min) => 20C/min => 100C(1min) => 3C/min => 190C(40min)25 0C (0.5 min) 50 K/min -> 50 0C 3.5 K/min -> 150 0C 7.5 K/min -> 240 0Cnot specified
I 1375.1375.1394.1375.1392.
ReferenceVinogradov, 2004Krings, Banavara, et al., 2003López and Dufour, 2001Miranda, Nogueira, et al., 2001Peng, Yang, et al., 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase DB-WaxCarbowax 20MCarbowax 20M
Column length (m)    
Carrier gas    
Substrate    
Column diameter (mm)    
Phase thickness (μm)    
Program not specifiednot specifiednot specified
I 1400.1375.1375.
ReferencePeng, Yang, et al., 1991Shibamoto, 1987Ramsey and Flanagan, 1982
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Vinogradov, 2004
Vinogradov, B.A., Production, composition, properties and application of essential oils, 2004, retrieved from http://viness.narod.ru. [all data]

Krings, Banavara, et al., 2003
Krings, U.; Banavara, D.S.; Berger, R.G., Thin layer high vacuum distillation to isolate the flavor of high-fat food, Eur. Food Res. Technol., 2003, 217, 1, 70-73, https://doi.org/10.1007/s00217-003-0700-9 . [all data]

López and Dufour, 2001
López, M.G.; Dufour, J.P., Chapter 6. Tequilas: charm analysis of Blanco, Teposado, and Anejo tequilas, Am. Chem. Soc. Symp. Ser., 2001, 782, 62-72. [all data]

Miranda, Nogueira, et al., 2001
Miranda, E.J.F.; Nogueira, R.I.; Pontes, S.M.; Rezende, C.M., Odour-active compounds of banana passa identified by aroma extract dilution analysis, Flavour Fragr. J., 2001, 16, 4, 281-285, https://doi.org/10.1002/ffj.997 . [all data]

Peng, Yang, et al., 1991
Peng, C.T.; Yang, Z.C.; Ding, S.F., Prediction of rentention idexes. II. Structure-retention index relationship on polar columns, J. Chromatogr., 1991, 586, 1, 85-112, https://doi.org/10.1016/0021-9673(91)80028-F . [all data]

Shibamoto, 1987
Shibamoto, T., Retention Indices in Essential Oil Analysis in Capillary Gas Chromatography in Essential Oil Analysis, Sandra, P.; Bicchi, C., ed(s)., Hutchig Verlag, Heidelberg, New York, 1987, 259-274. [all data]

Ramsey and Flanagan, 1982
Ramsey, J.D.; Flanagan, R.J., Detection and Identification of Volatile Organic Compounds in Blood by Headspace Gas Chromatography as an Aid to the Diagnosis of Solvent Abuse, J. Chromatogr., 1982, 240, 2, 423-444, https://doi.org/10.1016/S0021-9673(00)99622-5 . [all data]


Notes

Go To: Top, Normal alkane RI, polar column, custom temperature program, References