Benzene, chloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Ultra-ALLOY-5HP-5BP-1HP-5SE-54
Column length (m) 30.30.50.25.36.
Carrier gas  HeliumHe  
Substrate      
Column diameter (mm) 0.250.250.220.200.25
Phase thickness (μm) 0.250.250.750.330.25
Tstart (C) 40.50.50.50.35.
Tend (C) 320.280.200.180.240.
Heat rate (K/min) 20.3.5.5.5.
Initial hold (min) 2.3. 3. 
Final hold (min) 13.20.   
I 850.844.837.835.864.
ReferenceTsuge, Ohtan, et al., 2011Zenkevich, Moeder, et al., 2004Health Safety Executive, 2000Jung, Wichmann, et al., 1999Huang, Liang, et al., 1996
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101OV-101OV-101
Column length (m) 25.25.25.25.54.
Carrier gas     Helium
Substrate      
Column diameter (mm) 0.200.200.200.200.26
Phase thickness (μm)      
Tstart (C) 80.80.80.80.75.
Tend (C)     220.
Heat rate (K/min) 2.2.2.2.6.
Initial hold (min)     0.
Final hold (min)     0.
I 841.842.846.850.834.
ReferenceMessadi and Ali-Mokhnache, 1993Messadi and Ali-Mokhnache, 1993Messadi and Ali-Mokhnache, 1993Messadi and Ali-Mokhnache, 1993Zenkevich and Tsibulskaya, 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-101
Column length (m) 54.
Carrier gas Helium
Substrate  
Column diameter (mm) 0.26
Phase thickness (μm)  
Tstart (C) 75.
Tend (C) 220.
Heat rate (K/min) 6.
Initial hold (min) 0.
Final hold (min) 0.
I 839.
ReferenceZenkevich and Tsibulskaya, 1989
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tsuge, Ohtan, et al., 2011
Tsuge, S.; Ohtan, H.; Watanabe, C., Pyrolysis - GC/MS Data Book of Synthetic Polymers, Elsevier, 2011, 420. [all data]

Zenkevich, Moeder, et al., 2004
Zenkevich, I.G.; Moeder, M.; Koeller, G.; Schrader, S., Using new structurally related additive schemes in the precalculation of gas chromatographic retention indices of polychlorinated hydroxybiphenyls on HP-5 stationary phase, J. Chromatogr. A, 2004, 1025, 2, 227-236, https://doi.org/10.1016/j.chroma.2003.10.106 . [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Jung, Wichmann, et al., 1999
Jung, A.; Wichmann, K.-H.; Kolb, M., VOC emission of polymeric packaging materials, LaborPraxis, 1999, 23, 9, 20-22. [all data]

Huang, Liang, et al., 1996
Huang, C.; Liang, H.; Han, S., The analysis of organic compounds in waste water by gas extraction/thermal desorption/gas chromatography-mass spectrometry, Chin. J. Chromatogr., 1996, 14, 6, 421-424. [all data]

Messadi and Ali-Mokhnache, 1993
Messadi, D.; Ali-Mokhnache, S., Calculation of retention indices and peak widths in temperature programmed gas-liquid chromatography, Chromatographia, 1993, 37, 5/6, 264-270, https://doi.org/10.1007/BF02278631 . [all data]

Zenkevich and Tsibulskaya, 1989
Zenkevich, I.G.; Tsibulskaya, I.A., Influence of Relative Amounts of Mixture Components on the Precision of Measurements of Gas Chromatographic Retention Indices, Zh. Anal. Khim. (Rus.), 1989, 44, 1, 90-96. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References