Benzene, chloro-
- Formula: C6H5Cl
- Molecular weight: 112.557
- IUPAC Standard InChIKey: MVPPADPHJFYWMZ-UHFFFAOYSA-N
- CAS Registry Number: 108-90-7
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Chlorobenzene; Monochlorobenzene; MCB; Phenyl Chloride; Benzene chloride; Chlorbenzene; Chlorobenzol; Monochlorbenzene; Chloorbenzeen; Chlorbenzol; Chlorobenzen; Chlorobenzene, mono-; Clorobenzene; Monochloorbenzeen; Monochlorbenzol; Monoclorobenzene; NCI-C54886; Chlorobenzenu; UN 1134; Abluton T30; CP 27; IP Carrier T 40; NSC 8433; Tetrosin SP
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, non-polar column, temperature ramp
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | Ultra-ALLOY-5 | HP-5 | BP-1 | HP-5 | SE-54 |
Column length (m) | 30. | 30. | 50. | 25. | 36. |
Carrier gas | Helium | He | |||
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.22 | 0.20 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.75 | 0.33 | 0.25 |
Tstart (C) | 40. | 50. | 50. | 50. | 35. |
Tend (C) | 320. | 280. | 200. | 180. | 240. |
Heat rate (K/min) | 20. | 3. | 5. | 5. | 5. |
Initial hold (min) | 2. | 3. | 3. | ||
Final hold (min) | 13. | 20. | |||
I | 850. | 844. | 837. | 835. | 864. |
Reference | Tsuge, Ohtan, et al., 2011 | Zenkevich, Moeder, et al., 2004 | Health Safety Executive, 2000 | Jung, Wichmann, et al., 1999 | Huang, Liang, et al., 1996 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | OV-101 | OV-101 | OV-101 | OV-101 | OV-101 |
Column length (m) | 25. | 25. | 25. | 25. | 54. |
Carrier gas | Helium | ||||
Substrate | |||||
Column diameter (mm) | 0.20 | 0.20 | 0.20 | 0.20 | 0.26 |
Phase thickness (μm) | |||||
Tstart (C) | 80. | 80. | 80. | 80. | 75. |
Tend (C) | 220. | ||||
Heat rate (K/min) | 2. | 2. | 2. | 2. | 6. |
Initial hold (min) | 0. | ||||
Final hold (min) | 0. | ||||
I | 841. | 842. | 846. | 850. | 834. |
Reference | Messadi and Ali-Mokhnache, 1993 | Messadi and Ali-Mokhnache, 1993 | Messadi and Ali-Mokhnache, 1993 | Messadi and Ali-Mokhnache, 1993 | Zenkevich and Tsibulskaya, 1989 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary |
---|---|
Active phase | OV-101 |
Column length (m) | 54. |
Carrier gas | Helium |
Substrate | |
Column diameter (mm) | 0.26 |
Phase thickness (μm) | |
Tstart (C) | 75. |
Tend (C) | 220. |
Heat rate (K/min) | 6. |
Initial hold (min) | 0. |
Final hold (min) | 0. |
I | 839. |
Reference | Zenkevich and Tsibulskaya, 1989 |
Comment | MSDC-RI |
References
Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Tsuge, Ohtan, et al., 2011
Tsuge, S.; Ohtan, H.; Watanabe, C.,
Pyrolysis - GC/MS Data Book of Synthetic Polymers, Elsevier, 2011, 420. [all data]
Zenkevich, Moeder, et al., 2004
Zenkevich, I.G.; Moeder, M.; Koeller, G.; Schrader, S.,
Using new structurally related additive schemes in the precalculation of gas chromatographic retention indices of polychlorinated hydroxybiphenyls on HP-5 stationary phase,
J. Chromatogr. A, 2004, 1025, 2, 227-236, https://doi.org/10.1016/j.chroma.2003.10.106
. [all data]
Health Safety Executive, 2000
Health Safety Executive,
MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography
in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]
Jung, Wichmann, et al., 1999
Jung, A.; Wichmann, K.-H.; Kolb, M.,
VOC emission of polymeric packaging materials,
LaborPraxis, 1999, 23, 9, 20-22. [all data]
Huang, Liang, et al., 1996
Huang, C.; Liang, H.; Han, S.,
The analysis of organic compounds in waste water by gas extraction/thermal desorption/gas chromatography-mass spectrometry,
Chin. J. Chromatogr., 1996, 14, 6, 421-424. [all data]
Messadi and Ali-Mokhnache, 1993
Messadi, D.; Ali-Mokhnache, S.,
Calculation of retention indices and peak widths in temperature programmed gas-liquid chromatography,
Chromatographia, 1993, 37, 5/6, 264-270, https://doi.org/10.1007/BF02278631
. [all data]
Zenkevich and Tsibulskaya, 1989
Zenkevich, I.G.; Tsibulskaya, I.A.,
Influence of Relative Amounts of Mixture Components on the Precision of Measurements of Gas Chromatographic Retention Indices,
Zh. Anal. Khim. (Rus.), 1989, 44, 1, 90-96. [all data]
Notes
Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References
- Symbols used in this document:
Tend Final temperature Tstart Initial temperature - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.