Methyl Isobutyl Ketone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1HP-1HP-1HP-1HP-1
Column length (m)  50.50.50.50.
Carrier gas      
Substrate      
Column diameter (mm)  0.320.320.320.32
Phase thickness (μm)  1.051.051.051.05
Temperature (C) 333.110.30.50.70.
I 721.2722.94719.78720.12720.65
ReferenceHu, Lu, et al., 2006Héberger, Görgényi, et al., 2002Héberger, Görgényi, et al., 2002Héberger, Görgényi, et al., 2002Héberger, Görgényi, et al., 2002
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-1HP-1HP-1HP-1HP-1
Column length (m) 50.50.50.50.50.
Carrier gas  N2N2N2N2
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm) 1.051.051.051.051.05
Temperature (C) 90.110.50.70.90.
I 721.70723.720.721.722.
ReferenceHéberger, Görgényi, et al., 2002Héberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase SE-30OV-1SE-30Porapack QSE-30
Column length (m) 3.2.2. 3.7
Carrier gas Ar  N2 
Substrate Gas Chrom Q (80-100 mesh)Gas Chrom QGaschrom Q Celatom AW silanized
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 150.120.100.200.150.
I 730.726.724.727.727.
ReferenceTiess, 1984Valko, Papp, et al., 1984Winskowski, 1983Goebel, 1982Haken, Nguyen, et al., 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPacked
Active phase Apiezon LApiezon LApiezon L
Column length (m)   2.25
Carrier gas    
Substrate Celite 545Celite 545Celite
Column diameter (mm)    
Phase thickness (μm)    
Temperature (C) 120.160.130.
I 703.705.706.
ReferenceBogoslovsky, Anvaer, et al., 1978Bogoslovsky, Anvaer, et al., 1978Wehrli and Kováts, 1959
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Hu, Lu, et al., 2006
Hu, X.-F.; Lu, C.-H.; Yin, C.-S., Modeling Gas Chromatographic Retention Indices of Oxygen-containing Compounds by Novel Atom-type Topological Indices, Chinese Journal of Chemical Physics, 2006, 19, 3, 243-247, https://doi.org/10.1360/cjcp2006.19(3).243.5 . [all data]

Héberger, Görgényi, et al., 2002
Héberger, K.; Görgényi, M.; Kowalska, T., Temperature dependence of Kováts indices in gas chromatography revisited, J. Chromatogr. A, 2002, 973, 1-2, 135-142, https://doi.org/10.1016/S0021-9673(02)01198-6 . [all data]

Héberger and Görgényi, 1999
Héberger, K.; Görgényi, M., Principal component analysis of Kováts indices for carbonyl compounds in capillary gas chromatography, J. Chromatogr., 1999, 845, 1-2, 21-31, https://doi.org/10.1016/S0021-9673(99)00323-4 . [all data]

Tiess, 1984
Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]

Valko, Papp, et al., 1984
Valko, K.; Papp, O.; Darvas, F., Selection of Gas Chromatographic Stationary Phase Pairs for Characterization of the 1-Octanol-Water Partition Coefficient, J. Chromatogr., 1984, 301, 355-364, https://doi.org/10.1016/S0021-9673(01)89210-4 . [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Goebel, 1982
Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 1982, 235, 1, 119-127, https://doi.org/10.1016/S0021-9673(00)95793-5 . [all data]

Haken, Nguyen, et al., 1979
Haken, J.K.; Nguyen, A.; Wainwright, M.S., Application of linear extrathermodynamic relationships to alcohols, aldehydes, ketones, amd ethoxy alcohols, J. Chromatogr., 1979, 179, 1, 75-85, https://doi.org/10.1016/S0021-9673(00)80658-5 . [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Wehrli and Kováts, 1959
Wehrli, A.; Kováts, E., Gas-chromatographische Charakterisierung ogranischer Verbindungen. Teil 3: Berechnung der Retentionsindices aliphatischer, alicyclischer und aromatischer Verbindungen, Helv. Chim. Acta, 1959, 7, 7, 2709-2736, https://doi.org/10.1002/hlca.19590420745 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References