2-Pentanone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)      
Temperature (C) 40.50.60.70.80.
I 1003.891005.721007.521009.731011.09
ReferenceCiaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)      
Temperature (C) 90.100.110.120.130.
I 1012.781014.871016.301018.391020.31
ReferenceCiaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 30.30.30.30.30.
Carrier gas   HeHeHe
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm)   1.1.1.
Temperature (C) 140.150.75.100.125.
I 1022.251023.72986.781015.631021.54
ReferenceCiaznska-Halarewicz and Kowalska, 2003Ciaznska-Halarewicz and Kowalska, 2003Ciazynska-Halarewicz, Borucka, et al., 2002Ciazynska-Halarewicz, Borucka, et al., 2002Ciazynska-Halarewicz, Borucka, et al., 2002
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-InnowaxHP-InnowaxHP-InnowaxHP-InnowaxSupelcowax-10
Column length (m) 30.30.30.30.30.
Carrier gas     He
Substrate      
Column diameter (mm) 0.320.320.320.320.32
Phase thickness (μm) 0.50.50.50.50.25
Temperature (C) 110.50.70.90.60.
I 1010.7996.21000.71005.6990.2
ReferenceHéberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999Héberger and Görgényi, 1999Castello, Vezzani, et al., 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPackedPacked
Active phase PEG-20MPEG-20MPEG-20MCarbowax 20MPEG-20M
Column length (m) 50.50.50.3.52.
Carrier gas HeHeHeN2N2
Substrate    Chromosorb W-AWChromaton N AW HMDS
Column diameter (mm) 0.20.20.2  
Phase thickness (μm) 0.130.190.22  
Temperature (C) 80.80.80.80.120.
I 979.4992.6994.6979.996.
ReferenceOrav, Kuningas, et al., 1994Orav, Kuningas, et al., 1994Orav, Kuningas, et al., 1994Kersten and Poole, 1987Stolyarov and Kartsova, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ciaznska-Halarewicz and Kowalska, 2003
Ciaznska-Halarewicz, K.; Kowalska, T., A study of the dependence of the Kováts retention index on the temperature of analysis on stationary phases of different polarity, Acta Chromatogr., 2003, 13, 69-80. [all data]

Ciazynska-Halarewicz, Borucka, et al., 2002
Ciazynska-Halarewicz, K.; Borucka, H.E.; Kowalska, T., Temperature dependence of Kováts indices in gas chromatography. Statistical and thermodynamic verification of a 'kinetic' model, Acta Chromatogr., 2002, 12, 65-79. [all data]

Héberger and Görgényi, 1999
Héberger, K.; Görgényi, M., Principal component analysis of Kováts indices for carbonyl compounds in capillary gas chromatography, J. Chromatogr., 1999, 845, 1-2, 21-31, https://doi.org/10.1016/S0021-9673(99)00323-4 . [all data]

Castello, Vezzani, et al., 1994
Castello, G.; Vezzani, S.; Moretti, P., The selectivity and polarity of carbon layer open tubular capillary columns modified with a polar liquid phase, J. Hi. Res. Chromatogr., 1994, 17, 1, 31-36, https://doi.org/10.1002/jhrc.1240170108 . [all data]

Orav, Kuningas, et al., 1994
Orav, A.; Kuningas, K.; Kailas, T.; Koplimets, E.; Rang, S., Effect of adsorption on the retention values in capillary columns coated with OV-225 and PEG 20M, J. Chromatogr. A, 1994, 659, 1, 143-150, https://doi.org/10.1016/0021-9673(94)85016-X . [all data]

Kersten and Poole, 1987
Kersten, B.R.; Poole, C.F., Influence of concurrent retention mechanisms on the determination of stationary phase selectivity in gas chromatography, J. Chromatogr., 1987, 399, 1-31, https://doi.org/10.1016/S0021-9673(00)96108-9 . [all data]

Stolyarov and Kartsova, 1984
Stolyarov, B.V.; Kartsova, L.A., Comparative experimental estimation of polarity and selectivity of stationary phases in gas chromatography by means of Forschneider-McReynolds constants and on the basis of thermodynamic characteristics, Zh. Anal. Khim., 1984, 39, 5, 883-889. [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References