Benzene, heptyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-1DB-1Petrocol DHUltra-1Ultra-1
Column length (m) 10.30.100.50.50.
Carrier gas He HeHeHe
Substrate      
Column diameter (mm) 0.250.320.250.220.22
Phase thickness (μm) 0.251.50.50.330.33
Tstart (C) 30.40.30.-30.-30.
Tend (C) 225.280.220.240.240.
Heat rate (K/min) 2.8.1.1.2.
Initial hold (min)  4.   
Final hold (min)      
I 1337.1348.1349.1344.621349.17
ReferenceBeens, Tijssen, et al., 1998Peng, Hua, et al., 1992White, Hackett, et al., 1992Haynes and Pitzer, 1985Haynes and Pitzer, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Ultra-1Ultra-2Ultra-2Ultra-2OV-101
Column length (m) 50.50.50.50.108.
Carrier gas HeHeHeHe 
Substrate      
Column diameter (mm) 0.220.220.220.220.25
Phase thickness (μm) 0.330.330.330.330.2
Tstart (C) -30.-30.-30.-30.35.
Tend (C) 240.240.240.240.200.
Heat rate (K/min) 3.1.2.3.1.
Initial hold (min)      
Final hold (min)      
I 1351.941362.931367.671370.871348.
ReferenceHaynes and Pitzer, 1985Haynes and Pitzer, 1985Haynes and Pitzer, 1985Haynes and Pitzer, 1985Hayes and Pitzer, 1981
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Beens, Tijssen, et al., 1998
Beens, J.; Tijssen, R.; Blomberg, J., Prediction of comprehensive two-dimensional gas chromatographic separations. A theoretical and practical exercise, J. Chromatogr. A, 1998, 822, 2, 233-251, https://doi.org/10.1016/S0021-9673(98)00649-9 . [all data]

Peng, Hua, et al., 1992
Peng, C.T.; Hua, R.L.; Maltby, D., Prediction of retention indexes. IV. Chain branching in alkylbenzene isomers with C10-13 alkyl chains identified in a scintillator solvent, J. Chromatogr., 1992, 589, 1-2, 231-239, https://doi.org/10.1016/0021-9673(92)80027-R . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Haynes and Pitzer, 1985
Haynes, P.C., Jr.; Pitzer, E.W., Disengaging solutes in shale- and petroleum-derived jet fuels by altering GC programmed temperature rates, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 5, 230-242, https://doi.org/10.1002/jhrc.1240080504 . [all data]

Hayes and Pitzer, 1981
Hayes, P.C., Jr.; Pitzer, E.W., Kovats indices as a tool in characterizing hydrocarbon fuels in temperature programmed glass capillary gas chromatography. Part 1. Qualitative identification, Inhouse rpt. for Air Force Wright Aeronautical Labs., Air Force Wright Aeronautical Labs., Wright-Patterson AFB, Ohio, 1981, 75. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References