Ethane, 1,2-dichloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase Petrocol DHSE-54SE-54SE-54OV-101
Column length (m) 100.25.25.25.2.
Carrier gas HeH2H2H2Ar
Substrate     Supelcoport
Column diameter (mm) 0.250.310.310.31 
Phase thickness (μm) 0.50.170.170.17 
Tstart (C) 30.35.35.35.40.
Tend (C) 220.    
Heat rate (K/min) 1.2.2.2.8.
Initial hold (min)      
Final hold (min)      
I 620.641.643.648.660.0
ReferenceWhite, Hackett, et al., 1992Weber, 1986Weber, 1986Weber, 1986Zilka and Matucha, 1978
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase SE-30
Column length (m) 2.
Carrier gas Ar
Substrate Chromaton N-AW-DMCS
Column diameter (mm)  
Phase thickness (μm)  
Tstart (C) 40.
Tend (C)  
Heat rate (K/min) 8.
Initial hold (min)  
Final hold (min)  
I 628.6
ReferenceZilka and Matucha, 1978
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Weber, 1986
Weber, L., Utilization of the Sadtler standard RI system in micropollution analyses, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 8, 446-451, https://doi.org/10.1002/jhrc.1240090806 . [all data]

Zilka and Matucha, 1978
Zilka, L.; Matucha, M., Gas chromatographic analysis of chlorinated ethanes, J. Chromatogr., 1978, 148, 1, 229-235, https://doi.org/10.1016/S0021-9673(00)99342-7 . [all data]


Notes