Decanedioic acid, dimethyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryPackedPacked
Active phase DB-1DB-1DB-1SE-30SE-30
Column length (m) 30.30.30.2.2.
Carrier gas      
Substrate    Chromosorb QChromosorb Q
Column diameter (mm) 0.20.20.2  
Phase thickness (μm) 0.250.250.25  
Tstart (C) 50.50.50.100.100.
Tend (C) 300.300.300.  
Heat rate (K/min) 5.5.5.10.10.
Initial hold (min) 2.2.2.  
Final hold (min) 5.5.5.  
I 1611.1612.1611.1619.1631.
ReferenceJohnson, Urso, et al., 1997Johnson, Urso, et al., 1997Johnson, Urso, et al., 1997Helaimia and Messadi, 1989Helaimia and Messadi, 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPacked
Active phase OV-1DB-5SE-30
Column length (m) 25.30. 
Carrier gas HeHeN2
Substrate   Chromosorb Q
Column diameter (mm) 0.320.26 
Phase thickness (μm)  0.25 
Tstart (C) 40.50.100.
Tend (C) 280.300.340.
Heat rate (K/min) 8.6.10.
Initial hold (min)  4. 
Final hold (min) 10.20. 
I 1620.1649.1619.
ReferenceTan, Holland, et al., 1988Rostad and Pereira, 1986Messadi and Vergnaud, 1979
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Johnson, Urso, et al., 1997
Johnson, C.I.; Urso, A.; Geleta, L., Broad spectrum analysis of municipal and industrial effluents discharged into the Peace, Athabasca and Slave river basins: characterization of effluent samples, 1994 - Volume 1 of 2, Northern River Basins Study Project Report No. 121, Norther River Basins Study, Edmonton, Alberta, 1997, 27. [all data]

Helaimia and Messadi, 1989
Helaimia, F.; Messadi, D., Determination of linear programmed temperature gas chromatography retention indices for some plasticizers, C.R. Acad. Sci. Ser. 2:, 1989, 309, 37-42. [all data]

Tan, Holland, et al., 1988
Tan, S.-T.; Holland, P.T.; Wilkins, A.L.; Molan, P.C., Extractives from New Zealand honeys. 1. White clovers, manuka, and kanuka unifloral honeys, J. Agric. Food Chem., 1988, 36, 3, 453-460, https://doi.org/10.1021/jf00081a012 . [all data]

Rostad and Pereira, 1986
Rostad, C.E.; Pereira, W.E., Kovats and Lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 6, 328-334, https://doi.org/10.1002/jhrc.1240090603 . [all data]

Messadi and Vergnaud, 1979
Messadi, D.; Vergnaud, J.-M., Quick identification and analysis of plasticizers in PVC by programmed-temperature gas chromatography using the best stationary phases, J. Appl. Polym. Sci., 1979, 24, 5, 1215-1225, https://doi.org/10.1002/app.1979.070240507 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References