Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

p-Benzoquinone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSE-30180.905.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS; Column length: 2. m
PackedSE-30190.912.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS; Column length: 2. m
PackedSE-30200.919.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS; Column length: 2. m
PackedSE-30210.923.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS; Column length: 2. m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedCarbowax 20M180.1562.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS (60-80 mesh); Column length: 2. m
PackedCarbowax 20M190.1570.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS (60-80 mesh); Column length: 2. m
PackedCarbowax 20M200.1579.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS (60-80 mesh); Column length: 2. m
PackedCarbowax 20M210.1587.Llobera and García-Raso, 1987N2, Chromosorb P AW DMCS (60-80 mesh); Column length: 2. m

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryOV-101888.Zenkevich, 200525. m/0.20 mm/0.10 «mu»m, N2/He, 6. K/min; Tstart: 50. C; Tend: 250. C

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-5MS143.19Chen, Keeran, et al., 200230. m/0.25 mm/0.5 «mu»m, 40. C @ 1. min, 10. K/min; Tend: 310. C
CapillaryDB-5MS147.33Chen, Keeran, et al., 200230. m/0.25 mm/0.5 «mu»m, 40. C @ 1. min, 4. K/min; Tend: 310. C

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Llobera and García-Raso, 1987
Llobera, A.; García-Raso, A., Gas chromatographic behaviour of several p-quinones, J. Chromatogr., 1987, 393, 2, 305-311, https://doi.org/10.1016/S0021-9673(01)94227-X . [all data]

Zenkevich, 2005
Zenkevich, I.G., Experimentally measured retention indices., 2005. [all data]

Chen, Keeran, et al., 2002
Chen, P.H.; Keeran, W.S.; Van Ausdale, W.A.; Schindler, D.R.; Roberts, D.W., Application of Lee retention indices to the confirmation of tentatively identified compounds from GC/MS analysis of environmental samples, Technical paper, Analytical Services Division, Environmental ScienceEngineering, Inc, PO Box 1703, Gainesville, FL 32602, 2002, 11. [all data]


Notes

Go To: Top, Gas Chromatography, References