Benzene, 1,4-diethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillary
Active phase PEG-20MCarbowax 20MCarbowax 20MCarbowax 20M
Column length (m) 30. 100.100.
Carrier gas N2 N2 
Substrate     
Column diameter (mm) 0.3 0.230.2
Phase thickness (μm)     
Temperature (C) 70.90.100.90.
I 1305.21283.61289.41283.6
ReferenceTóth, 1983Kuchhal, Kumar, et al., 1980Engewald and Wennrich, 1976Döring, Estel, et al., 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tóth, 1983
Tóth, T., Use of capillary gas chromatography in collecting retention and chemical information for the analysis of complex petrochemical mixtures, J. Chromatogr., 1983, 279, 157-165, https://doi.org/10.1016/S0021-9673(01)93614-3 . [all data]

Kuchhal, Kumar, et al., 1980
Kuchhal, R.K.; Kumar, B.; Kumar, P.; Gupta, P.L., Determination of the isomeric distribution and associated impurities in commercial diethylbenzenes by capillary gas chromatography, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1980, 3, 10, 497-502, https://doi.org/10.1002/jhrc.1240031003 . [all data]

Engewald and Wennrich, 1976
Engewald, W.; Wennrich, L., Molekülstruktur und Retentionsverhalten. VIII. Zum Retentionsverhalten höherer Alkylbenzole bei der Gas-Verteilungs-Chromatographie, Chromatographia, 1976, 9, 11, 540-547, https://doi.org/10.1007/BF02275960 . [all data]

Döring, Estel, et al., 1974
Döring, C.E.; Estel, D.; Fischer, R., Kapillar-gaschromatographische Charakterisierung von C10-bis C12-Aromaten, J. Prakt. Chem., 1974, 316, 1, 1-12, https://doi.org/10.1002/prac.19743160102 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References