Benzene, n-butyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5MSCP-Sil 8CB-MSDB-5DB-5DB-5
Column length (m) 20.0.30.30.30.
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.250.25
Tstart (C) 60.40.40.40.40.
Tend (C) 240.280.310.310.310.
Heat rate (K/min) 5.4.4.4.2.
Initial hold (min) 4.2. 5. 
Final hold (min) 15.5.   
I 1058.1061.1053.71053.31050.1
ReferenceKallio, Jussila, et al., 2006Elmore, Cooper, et al., 2005Song, Lai, et al., 2003Song, Lai, et al., 2003Song, Lai, et al., 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-1HP-5OV-101
Column length (m) 30.30.30.30.80.
Carrier gas HeHeHeHeN2
Substrate      
Column diameter (mm) 0.250.250.250.250.22
Phase thickness (μm) 0.250.250.250.25 
Tstart (C) 40.40.40.40.30.
Tend (C) 310.310.325.180.130.
Heat rate (K/min) 4.6.3.3.1.
Initial hold (min)      
Final hold (min)      
I 1053.71055.91036.41054.1042.0
ReferenceSong, Lai, et al., 2003Song, Lai, et al., 2003Sun and Stremple, 2003Isidorov, Krajewska, et al., 2001Yin, Liu, et al., 2001
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-1OV-1DB-5DB-5DB-5
Column length (m) 10. 30.30.30.
Carrier gas He HeHeHe
Substrate      
Column diameter (mm) 0.25 0.250.250.25
Phase thickness (μm) 0.25 0.250.250.25
Tstart (C) 30.35.40.40.40.
Tend (C) 225.300.310.310.310.
Heat rate (K/min) 2.8.2.4.6.
Initial hold (min)      
Final hold (min)      
I 1030.1043.21050.11053.71055.9
ReferenceBeens, Tijssen, et al., 1998Gautzsch and Zinn, 1996Lai and Song, 1995Lai and Song, 1995Lai and Song, 1995
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-1DB-1Petrocol DH
Column length (m) 30.30.60.30.100.
Carrier gas HeHeHe He
Substrate      
Column diameter (mm) 0.250.250.250.320.25
Phase thickness (μm) 0.250.251.01.50.5
Tstart (C) 40.40.40.40.30.
Tend (C) 310.310.260.280.220.
Heat rate (K/min) 4.4.2.8.1.
Initial hold (min)  5.5.4. 
Final hold (min)   60.  
I 1053.71053.31054.1047.1041.77
ReferenceLai and Song, 1995Lai and Song, 1995Yu, Lin, et al., 1994Peng, Hua, et al., 1992White, Douglas, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHPetrocol DHUltra-2Ultra-2Ultra-2
Column length (m) 100.100.25.25.25.
Carrier gas HeHeN2N2N2
Substrate      
Column diameter (mm) 0.250.250.20.20.2
Phase thickness (μm) 0.50.50.330.330.33
Tstart (C) 30.30.60.0160.0160.01
Tend (C) 220.220.   
Heat rate (K/min) 1.1.15.2.7.
Initial hold (min)      
Final hold (min)      
I 1042.191042.1066.41056.41062.2
ReferenceWhite, Douglas, et al., 1992White, Hackett, et al., 1992Akporhonor, le Vent, et al., 1990Akporhonor, le Vent, et al., 1990Akporhonor, le Vent, et al., 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Ultra-2Ultra-2Ultra-2DB-5Ultra-1
Column length (m) 25.25.25.15.50.
Carrier gas N2N2N2HeHe
Substrate      
Column diameter (mm) 0.20.20.20.530.22
Phase thickness (μm) 0.330.330.331.50.33
Tstart (C) 120.01120.01120.0140.-30.
Tend (C)    90.240.
Heat rate (K/min) 15.2.7.4.1.
Initial hold (min)      
Final hold (min)      
I 1078.1071.81074.51051.1037.42
ReferenceAkporhonor, le Vent, et al., 1990Akporhonor, le Vent, et al., 1990Akporhonor, le Vent, et al., 1990Morinaga, Hara, et al., 1990Haynes and Pitzer, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Ultra-1Ultra-1Ultra-2Ultra-2Ultra-2
Column length (m) 50.50.50.50.50.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.220.220.220.220.22
Phase thickness (μm) 0.330.330.330.330.33
Tstart (C) -30.-30.-30.-30.-30.
Tend (C) 240.240.240.240.240.
Heat rate (K/min) 2.3.1.2.3.
Initial hold (min)      
Final hold (min)      
I 1040.681043.021054.181057.891060.55
ReferenceHaynes and Pitzer, 1985Haynes and Pitzer, 1985Haynes and Pitzer, 1985Haynes and Pitzer, 1985Haynes and Pitzer, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-101
Column length (m) 108.
Carrier gas  
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm) 0.2
Tstart (C) 35.
Tend (C) 200.
Heat rate (K/min) 1.
Initial hold (min)  
Final hold (min)  
I 1040.
ReferenceHayes and Pitzer, 1981
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kallio, Jussila, et al., 2006
Kallio, M.; Jussila, M.; Rissanen, T.; Anttila, P.; Hartonen, K.; Reissell, A.; Vreuls, R.; Adahchour, M.; Hyotylainen, T., Comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry in the identification of organic compounds in atmospheric aerosols from coniferous forest, J. Chromatogr. A, 2006, 1125, 2, 234-243, https://doi.org/10.1016/j.chroma.2006.05.050 . [all data]

Elmore, Cooper, et al., 2005
Elmore, J.S.; Cooper, S.L.; Enser, M.; Mottram, D.S.; Sinclair, L.A.; Wilkinson, R.G.; Wood, J.D., Dietary manipulation of fatty acid composition in lamb meat and its effect on the volatile aroma compounds of grilled lamb, Meat Sci., 2005, 69, 2, 233-242, https://doi.org/10.1016/j.meatsci.2004.07.002 . [all data]

Song, Lai, et al., 2003
Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s)., Kluwer Academic/Plenum Publishers, New York, 2003, 147-193. [all data]

Sun and Stremple, 2003
Sun, G.; Stremple, P., Retention index characterization of flavor, fragrance, and many other compounds on DB-1 and DB-XLB, 2003, retrieved from http://www.chem.agilent.com/cag/cabu/pdf/b-0279.pdf. [all data]

Isidorov, Krajewska, et al., 2001
Isidorov, V.A.; Krajewska, U.; Dubis, E.N.; Jdanova, M.A., Partition coefficients of alkyl aromatic hydrocarbons and esters in a hexane-acetonitrile system, J. Chromatogr. A, 2001, 923, 1-2, 127-136, https://doi.org/10.1016/S0021-9673(01)00929-3 . [all data]

Yin, Liu, et al., 2001
Yin, C.; Liu, W.; Li, Z.; Pan, Z.; Lin, T.; Zhang, M., Chemometrics to chemical modeling: structural coding in hydrocarbons and retention indices of gas chromatography, J. Sep. Sci., 2001, 24, 3, 213-220, https://doi.org/10.1002/1615-9314(20010301)24:3<213::AID-JSSC213>3.0.CO;2-4 . [all data]

Beens, Tijssen, et al., 1998
Beens, J.; Tijssen, R.; Blomberg, J., Prediction of comprehensive two-dimensional gas chromatographic separations. A theoretical and practical exercise, J. Chromatogr. A, 1998, 822, 2, 233-251, https://doi.org/10.1016/S0021-9673(98)00649-9 . [all data]

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

Lai and Song, 1995
Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 1995, 74, 10, 1436-1451, https://doi.org/10.1016/0016-2361(95)00108-H . [all data]

Yu, Lin, et al., 1994
Yu, T.-H.; Lin, L.-Y.; Ho, C.-T., Volatile compounds of blanched, fried blanched, and baked blanched garlic slices, J. Agric. Food Chem., 1994, 42, 6, 1342-1347, https://doi.org/10.1021/jf00042a018 . [all data]

Peng, Hua, et al., 1992
Peng, C.T.; Hua, R.L.; Maltby, D., Prediction of retention indexes. IV. Chain branching in alkylbenzene isomers with C10-13 alkyl chains identified in a scintillator solvent, J. Chromatogr., 1992, 589, 1-2, 231-239, https://doi.org/10.1016/0021-9673(92)80027-R . [all data]

White, Douglas, et al., 1992
White, C.M.; Douglas, L.J.; Hackett, J.P.; Anderson, R.R., Characterization of synthetic gasoline from the chloromethane-zeolite reaction, Energy Fuels, 1992, 6, 1, 76-82, https://doi.org/10.1021/ef00031a012 . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Akporhonor, le Vent, et al., 1990
Akporhonor, E.E.; le Vent, S.; Taylor, D.R., Calculation of programmed temperature gas chromatographic characteristics from isothermal data. III. Predicted retention indices and equivalent temperatures, J. Chromatogr., 1990, 504, 269-278, https://doi.org/10.1016/S0021-9673(01)89532-7 . [all data]

Morinaga, Hara, et al., 1990
Morinaga, M.; Hara, K.; Kageura, M.; Heida, Y.; Takamoto, M.; Kashimura, S., A simple, rapid and simultaneous analysis of complex volatile hydrocarbon mixtures in blood using gas chromatography/mass spectrometry with a wide-bore capillary column, Z. Rechtsmed., 1990, 103, 8, 567-572, https://doi.org/10.1007/BF01261420 . [all data]

Haynes and Pitzer, 1985
Haynes, P.C., Jr.; Pitzer, E.W., Disengaging solutes in shale- and petroleum-derived jet fuels by altering GC programmed temperature rates, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 5, 230-242, https://doi.org/10.1002/jhrc.1240080504 . [all data]

Hayes and Pitzer, 1981
Hayes, P.C., Jr.; Pitzer, E.W., Kovats indices as a tool in characterizing hydrocarbon fuels in temperature programmed glass capillary gas chromatography. Part 1. Qualitative identification, Inhouse rpt. for Air Force Wright Aeronautical Labs., Air Force Wright Aeronautical Labs., Wright-Patterson AFB, Ohio, 1981, 75. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References