Benzyl methyl ketone

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5MSHP-5 MSDB-1DB-1DB-1
Column length (m) 30.30.30.60.60.
Carrier gas HeHeliumHe  
Substrate      
Column diameter (mm) 0.250.250.320.320.32
Phase thickness (μm) 0.250.250.50.250.25
Tstart (C) 60.60.35.50.50.
Tend (C) 250.250.200.250.250.
Heat rate (K/min) 2.2.10.4.4.
Initial hold (min) 8.8.1.  
Final hold (min) 15.15.   
I 1124.1124.1116.1090.1091.
ReferenceFerhat, Tigrine-Kordjani, et al., 2007Tigrine-Kordiani, Meklati, et al., 2006Robacker and Bartelt, 1997Flath, Matsumoto, et al., 1989Flath, Matsumoto, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase DB-1DB-1
Column length (m) 60.60.
Carrier gas   
Substrate   
Column diameter (mm) 0.320.32
Phase thickness (μm) 0.250.25
Tstart (C) 50.50.
Tend (C) 250.250.
Heat rate (K/min) 4.4.
Initial hold (min)   
Final hold (min)   
I 1091.1093.
ReferenceFlath, Matsumoto, et al., 1989Flath, Matsumoto, et al., 1989
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Ferhat, Tigrine-Kordjani, et al., 2007
Ferhat, M.A.; Tigrine-Kordjani, N.; Chemat, S.; Meklati, B.Y.; Chemat, F., Rapid Extraction of Volatile Compounds Using a New Simultaneous Microwave Distillation: Solvent Extraction Device, Chromatographia, 2007, 65, 3-4, 217-222, https://doi.org/10.1365/s10337-006-0130-5 . [all data]

Tigrine-Kordiani, Meklati, et al., 2006
Tigrine-Kordiani, N.; Meklati, B.Y.; Chemat, F., Abalysis by gas chromatography - mass spectrometry of the essential oil of Zygophyllum album L., an aromatic and medicinal plant growing in Algeria, Int. J. Aromatherapy, 2006, 16, 3-4, 187-191, https://doi.org/10.1016/j.ijat.2006.09.008 . [all data]

Robacker and Bartelt, 1997
Robacker, D.C.; Bartelt, R.J., Chemicals attractive to Mexican fruit fly from Klebsiella pneumoniae and Citrobacter freundii cultures sampled by solid-phase microextraction MICROEXTRACTION, J. Chem. Ecol., 1997, 23, 12, 2897-2915, https://doi.org/10.1023/A:1022579414233 . [all data]

Flath, Matsumoto, et al., 1989
Flath, R.A.; Matsumoto, K.E.; Binder, R.G.; Cunningham, R.T.; Mon, T.R., Effect of pH on the volatiles of hydrolyzed protein insect baits, J. Agric. Food Chem., 1989, 37, 3, 814-819, https://doi.org/10.1021/jf00087a053 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References