Benzeneacetic acid, ethyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-WaxOV-351ZB-WaxOV-351Supelcowax-10
Column length (m) 30.50.30.50.60.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.320.320.250.320.25
Phase thickness (μm) 0.50.20.150.20.25
Tstart (C) 40.60.35.60.35.
Tend (C) 265.220.220.220.195.
Heat rate (K/min) 7.5.1.85.2.
Initial hold (min)   10.  
Final hold (min) 5. 10. 90.
I 1779.1775.1783.1775.1793.
ReferenceGurbuz O., Rouseff J.M., et al., 2006Bonvehí, 2005Ledauphin, Saint-Clair, et al., 2004Bonvehi and Coll, 2003Chung, 2000
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Supelcowax-10DB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 60.30.30.30.30.
Carrier gas HeHe   
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.25    
Tstart (C) 35.40.50.50.50.
Tend (C) 195.200.240.240.240.
Heat rate (K/min) 2.2.2.2.2.
Initial hold (min) 5.10.   
Final hold (min) 90.    
I 1793.1776.1778.51781.81781.8
ReferenceChung, 1999Umano, Hagi, et al., 1992Chang, Sheng, et al., 1989Chang, Sheng, et al., 1989Chang, Sheng, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase DB-Wax
Column length (m) 30.
Carrier gas  
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm)  
Tstart (C) 50.
Tend (C) 240.
Heat rate (K/min) 2.
Initial hold (min)  
Final hold (min)  
I 1784.7
ReferenceChang, Sheng, et al., 1989
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Gurbuz O., Rouseff J.M., et al., 2006
Gurbuz O.; Rouseff J.M.; Rouseff R.L., Comparison of aroma volatiles in commercial Merlot and Cabernet Sauvignon wines using gas chromatography - Olfactometry and gas chromatography - Mass spectrometry, J. Agric. Food Chem., 2006, 54, 11, 3990-3996, https://doi.org/10.1021/jf053278p . [all data]

Bonvehí, 2005
Bonvehí, J.S., Investigation of aromatic compounds in roasted cocoa powder, Eur. Food Res. Technol., 2005, 221, 1-2, 19-29, https://doi.org/10.1007/s00217-005-1147-y . [all data]

Ledauphin, Saint-Clair, et al., 2004
Ledauphin, J.; Saint-Clair, J.-F.; Lablanquie, O.; Guichard, H.; Founier, N.; Guichard, E.; Barillier, D., Identification of trace volatile compounds in freshly distilled calvados and cognac using preparative separations coupled with gas chromatography-mass spectrometry, J. Agric. Food Chem., 2004, 52, 16, 5124-5134, https://doi.org/10.1021/jf040052y . [all data]

Bonvehi and Coll, 2003
Bonvehi, J.S.; Coll, F.V., Flavour index and aroma profiles of fresh and processed honeys, J. Sci. Food Agric., 2003, 83, 4, 275-282, https://doi.org/10.1002/jsfa.1308 . [all data]

Chung, 2000
Chung, H.Y., Volatile flavor components in red fermented soybean (Glycine max) curds, J. Agric. Food Chem., 2000, 48, 5, 1803-1809, https://doi.org/10.1021/jf991272s . [all data]

Chung, 1999
Chung, H.Y., Volatile components in fermented soybean (Glycine max) curds, J. Agric. Food Chem., 1999, 47, 7, 2690-2696, https://doi.org/10.1021/jf981166a . [all data]

Umano, Hagi, et al., 1992
Umano, K.; Hagi, Y.; Nakahara, K.; Shoji, A.; Shibamoto, T., Volatile constituents of green and ripened pineapple (Aanas comosus [L.] Merr.), J. Agric. Food Chem., 1992, 40, 4, 599-603, https://doi.org/10.1021/jf00016a014 . [all data]

Chang, Sheng, et al., 1989
Chang, L.P.; Sheng, L.S.; Yang, M.Z.; An, D.K., Retention index of essential oil in temperature-programmed capillary column gas chromatography, Acta Pharm. Sin., 1989, 24, 11, 847-852. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, References