Styrene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryPackedPacked
Active phase Carbowax 20MCarbowax 20MPEG-20MCarbowax 20MCarbowax 20M
Column length (m) 50.50.30.  
Carrier gas N2N2N2  
Substrate    Chromosorb W, AW-DMCSChromosorb G
Column diameter (mm) 0.320.320.3  
Phase thickness (μm) 0.30.3   
Temperature (C) 110.120.70.150.115.
I 1291.71300.1255.11283.81281.9
ReferenceBoneva and Vassilev, 1996Boneva and Vassilev, 1996Tóth, 1983Ellis and Still, 1979Ellis and Still, 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Carbowax 20MCarbowax 20MCarbowax 20MCarbowax 20MCarbowax 20M
Column length (m)      
Carrier gas      
Substrate Chromosorb GChromosorb W, AW-DMCSChromosorb W, AW-DMCSChromosorb W, AW-DMCSChromosorb W, AW-DMCS
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 115.150.165.165.165.
I 1282.61284.81293.51293.51295.
ReferenceEllis and Still, 1979Ellis and Still, 1979Ellis and Still, 1979, 2Ellis and Still, 1979, 2Ellis and Still, 1979, 2
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPacked
Active phase Carbowax 20MCarbowax 20M
Column length (m) 100.2.
Carrier gas   
Substrate   
Column diameter (mm) 0.2 
Phase thickness (μm)   
Temperature (C) 90.100.
I 1228.71275.
ReferenceDöring, Estel, et al., 1974Rohrschneider, 1966
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Boneva and Vassilev, 1996
Boneva, S.; Vassilev, K., Gas chromatographic separation of epoxystyrenes on carbowax 20 M capillary column, Chromatographia, 1996, 43, 3/4, 208-210, https://doi.org/10.1007/BF02292953 . [all data]

Tóth, 1983
Tóth, T., Use of capillary gas chromatography in collecting retention and chemical information for the analysis of complex petrochemical mixtures, J. Chromatogr., 1983, 279, 157-165, https://doi.org/10.1016/S0021-9673(01)93614-3 . [all data]

Ellis and Still, 1979
Ellis, T.S.; Still, R.H., Thermal degradation of polymers. XXI. Vacuum pyrolysis of poly(m-N,N-dimethylaminostyrene); the products volatile at pyrolysis temperature, liquid at room temperature, J. Appl. Polym. Sci., 1979, 23, 10, 2837-2854, https://doi.org/10.1002/app.1979.070231002 . [all data]

Ellis and Still, 1979, 2
Ellis, T.S.; Still, R.H., Thermal degradation of polymers. XXIII. Vacuum pyrolysis of poly(p-N,N-dimethylaminostyrene); the products volatile at pyrolysis temperature, liquid or gaseous at room temperature, J. Appl. Polym. Sci., 1979, 23, 10, 2871-2880, https://doi.org/10.1002/app.1979.070231004 . [all data]

Döring, Estel, et al., 1974
Döring, C.E.; Estel, D.; Fischer, R., Kapillar-gaschromatographische Charakterisierung von C10-bis C12-Aromaten, J. Prakt. Chem., 1974, 316, 1, 1-12, https://doi.org/10.1002/prac.19743160102 . [all data]

Rohrschneider, 1966
Rohrschneider, L., Eine methode zur charakterisierung von gaschromatographischen trennflüssigkeiten, J. Chromatogr., 1966, 22, 6-22, https://doi.org/10.1016/S0021-9673(01)97064-5 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References