Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

NOTICE: Due to scheduled maintenance at our Gaithersburg campus, this site will not be available from 5:00 pm EDT (21:00 UTC) on Friday October 25 until 5:00 pm (21:00 UTC) on Sunday October 27. We apologize for any inconvenience this outage may cause.

Mercury bromide


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. - 6000.
A 37.40588
B 1.139710
C -0.002123
D 0.000181
E -0.047760
F 92.81869
G 316.1962
H 104.1820
ReferenceChase, 1998
Comment Data last reviewed in December, 1961
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.37.21271.5271.5-0.01
300.37.22271.8271.50.07
400.37.56282.5273.03.81
500.37.78290.9275.87.58
600.37.96297.8278.911.36
700.38.11303.7282.015.17
800.38.24308.8285.118.99
900.38.37313.3288.022.82
1000.38.50317.4290.726.66
1100.38.62321.0293.330.52
1200.38.74324.4295.734.38
1300.38.86327.5298.138.26
1400.38.97330.4300.342.15
1500.39.09333.1302.446.06
1600.39.21335.6304.449.97
1700.39.32338.0306.353.90
1800.39.44340.2308.157.84
1900.39.55342.4309.961.79
2000.39.67344.4311.565.75
2100.39.78346.3313.169.72
2200.39.90348.2314.773.70
2300.40.01350.0316.277.70
2400.40.12351.7317.681.70
2500.40.24353.3319.085.72
2600.40.35354.9320.489.75
2700.40.46356.4321.793.79
2800.40.58357.9323.097.85
2900.40.69359.3324.2101.9
3000.40.81360.7325.4106.0
3100.40.92362.0326.5110.1
3200.41.03363.3327.7114.2
3300.41.15364.6328.8118.3
3400.41.26365.8329.8122.4
3500.41.37367.0330.9126.5
3600.41.49368.2331.9130.7
3700.41.60369.3332.9134.8
3800.41.71370.5333.9139.0
3900.41.83371.5334.8143.2
4000.41.94372.6335.8147.4
4100.42.05373.6336.7151.6
4200.42.17374.7337.6155.8
4300.42.28375.6338.4160.0
4400.42.39376.6339.3164.2
4500.42.51377.6340.1168.5
4600.42.62378.5341.0172.7
4700.42.73379.4341.8177.0
4800.42.85380.3342.6181.3
4900.42.96381.2343.3185.6
5000.43.07382.1344.1189.9
5100.43.19382.9344.9194.2
5200.43.30383.8345.6198.5
5300.43.41384.6346.3202.8
5400.43.53385.4347.0207.2
5500.43.64386.2347.7211.5
5600.43.75387.0348.4215.9
5700.43.87387.8349.1220.3
5800.43.98388.5349.8224.7
5900.44.09389.3350.5229.1
6000.44.21390.0351.1233.5

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References