Search Results

Search criteria:

Author:Cramers, C.

You may also wish to search for items by Cramers.

13 matching references were found.

Snijders, H.; Janssen, H.-G.; Cramers, C., Optimization of temperature-programmed gas chromatographic separations. I. Prediction of retention times and peak widths from retention indices, J. Chromatogr. A, 1995, 718, 2, 339-355, https://doi.org/10.1016/0021-9673(95)00692-3 . [all data]

van Es, A.; Janssen, J.; Cramers, C.; Rijks, J., Sample enrichment in high speed narrow bore capillary gas chromatography, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1988, 11, 12, 852-857, https://doi.org/10.1002/jhrc.1240111202 . [all data]

van Deursen, M.; Janssen, H.-G.; Beens, J.; Rutten, G.; Cramers, C., Design considerations for rapid-heating columns applied in fast capillary gas chromatography, J. Microcolumn Sep., 2001, 13, 8, 337-345, https://doi.org/10.1002/mcs.10016 . [all data]

Curvers, J.; Rijks, J.; Cramers, C.; Knauss, K.; Larson, P., Temperature programmed retention indexes: calculation from isothermal data. Part 2. Results with nonpolar columns, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 9, 611-617, https://doi.org/10.1002/jhrc.1240080927 . [all data]

Curvers, J.; Rijks, J.; Cramers, C.; Knauss, K.; Larson, P., Temperature programmed retention indices: calculation from isothermal data. Part 1: Theory, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 9, 607-610, https://doi.org/10.1002/jhrc.1240080926 . [all data]

Rijks, J.A.; Cramers, C.A., High precision capillary gas chromatography of hydrocarbons, Chromatographia, 1974, 7, 3, 99-106, https://doi.org/10.1007/BF02269819 . [all data]

Mol, H.G.J.; Althuizen, M.; Janssen, H.-G.; Cramers, C.A.; Brinkman, U.A.Th., Environmental applications of large volume injection in capillary GC using PTV injectors, J. Hi. Res. Chromatogr., 1996, 19, 2, 69-79, https://doi.org/10.1002/jhrc.1240190203 . [all data]

Wu, Q.; Hetem, M.; Cramers, C.A.; Rijks, J.A., Preparation of thermally stable phenylpolysiloxane fused silica capillary columns. Optimization and evaluation of the deactivation by capillary GC and solid state 29Si NMR, J. Hi. Res. Chromatogr., 1990, 13, 12, 811-816, https://doi.org/10.1002/jhrc.1240131204 . [all data]

van Lieshout, M.H.P.M.; Janssen, H.-G.; Cramers, C.A.; Hetem, M.J.J.; Schalk, H.J.P., Characterization of polymers by multi-step thermal desorption/programmed pyrolysis gas chromatography using a high temperature PTV injector, J. Hi. Res. Chromatogr., 1996, 19, 4, 193-199, https://doi.org/10.1002/jhrc.1240190404 . [all data]

van Deursen, M.; Beens, J.; Cramers, C.A.; Janssen, H.-G., Possibilities and limitations of fast temperature programming as a route towards fast GC, J. Hi. Res. Chromatogr., 1999, 22, 9, 509-513, https://doi.org/10.1002/(SICI)1521-4168(19990901)22:9<509::AID-JHRC509>3.0.CO;2-S . [all data]

Cramers, C.A.; Rijks, J.A.; Pacáková, V.; de Andrade, I.R., The application of precision gas chromatography to the identification of types of hydrocarbons, J. Chromatogr., 1970, 51, 13-21, https://doi.org/10.1016/S0021-9673(01)96835-9 . [all data]

Svob, V.; Deur-Siftar, D.; Cramers, C.A., Mechanisms of the thermal degradation of alkylbenzenes, J. Chromatogr., 1974, 91, 659-675, https://doi.org/10.1016/S0021-9673(01)97946-4 . [all data]

Cramers, C.A.M.G.; Keulemans, A.I.M., Pyrolysis of volatile substances (Kinetics and product studies), J. Gas Chromatogr., 1967, 5, 2, 58-64, https://doi.org/10.1093/chromsci/5.2.58 . [all data]