1-Octanamine

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Gas Chromatography

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedSE-30170.993.Voelkel, 1987He, Chromaton N Super (75-100 mesh); Column length: 1. m
PackedSE-30180.1038.Oszczapowicz, Osek, et al., 1985N2, Chromosorb A AW; Column length: 3. m
PackedApiezon L100.1041.Golovnya and Zhuravleva, 1973 
PackedApiezon L130.1022.Landault and Guiochon, 1964Teflon-Haloport; Column length: 2.26 m

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedPEG-2000150.1320.Anderson, Jurel, et al., 1973He, Celite 545 (44-60 mesh); Column length: 3. m
PackedPEG-2000152.1320.Anderson, Jurel, et al., 1973He, Celite 545 (44-60 mesh); Column length: 3. m
PackedPEG-2000179.1318.Anderson, Jurel, et al., 1973He, Celite 545 (44-60 mesh); Column length: 3. m
PackedPEG-2000180.1317.Anderson, Jurel, et al., 1973He, Celite 545 (44-60 mesh); Column length: 3. m
PackedPEG-2000200.1315.Anderson, Jurel, et al., 1973He, Celite 545 (44-60 mesh); Column length: 3. m

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillarySE-541038.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541042.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541043.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541044.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541046.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541047.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541047.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541049.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541051.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541057.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C
CapillarySE-541058.Woolley, Markides, et al., 198620. m/0.05 mm/0.25 μm, He, 40. C @ 2. min, 4. K/min; Tend: 180. C

Van Den Dool and Kratz RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-11032.Peng, 200015. m/0.53 mm/1. μm, He; Program: 40C(3min) => 8C/min => 200(1min) => 5C/min => 300C(25min)

Van Den Dool and Kratz RI, polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-Wax1316.Peng, 200015. m/0.53 mm/1. μm, He, 40. C @ 3. min, 5. K/min, 220. C @ 30. min

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryUltra-11028.Okumura, 199125. m/0.32 mm/0.25 μm, He, 3. K/min; Tstart: 80. C; Tend: 260. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone1041.Chen and Feng, 2007Program: not specified

References

Go To: Top, Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Voelkel, 1987
Voelkel, A., Retention Indices and Thermodynamic Functions of Solution for Model Non-Ionic Surfactants in Standard Stationary Phases Determined by Gas Chromatography, J. Chromatogr., 1987, 387, 95-104, https://doi.org/10.1016/S0021-9673(01)94516-9 . [all data]

Oszczapowicz, Osek, et al., 1985
Oszczapowicz, J.; Osek, J.; Ciszkowski, K.; Krawczyk, W.; Ostrowski, M., Retention Indices of Dimethylbenzamidines and Benzylideneamines on a Non-Polar Column, J. Chromatogr., 1985, 330, 79-85, https://doi.org/10.1016/S0021-9673(01)81964-6 . [all data]

Golovnya and Zhuravleva, 1973
Golovnya, R.V.; Zhuravleva, I.L., Gas Chromatographic Method of Identification of n-Aliphatic Amines Through the Use of Donor-Acceptor Interaction with Phosphate, Chromatographia, 1973, 6, 12, 508-513, https://doi.org/10.1007/BF02269131 . [all data]

Landault and Guiochon, 1964
Landault, C.; Guiochon, G., Separation des amines par chromatographie gaz-liquide en utilisant le teflon comme support, J. Chromatogr., 1964, 13, 327-336, https://doi.org/10.1016/S0021-9673(01)95126-X . [all data]

Anderson, Jurel, et al., 1973
Anderson, A.; Jurel, S.; Shymanska, M.; Golender, L., Gas-liquid chromatography of some aliphatic and heterocyclic mono- and pollyfunctional amines. VII. Retention indices of amines in some polar and unpolar stationary phases, Latv. PSR Zinat. Akad. Vestis Kim. Ser., 1973, 1, 51-63. [all data]

Woolley, Markides, et al., 1986
Woolley, C.L.; Markides, K.E.; Lee, M.L.; Bartle, K.D., Deactivation of small diameter fused silica capillary columns with organosilicon hydrides, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 9, 506-514, https://doi.org/10.1002/jhrc.1240090904 . [all data]

Peng, 2000
Peng, C.T., Prediction of retention indices. V. Influence of electronic effects and column polarity on retention index, J. Chromatogr. A, 2000, 903, 1-2, 117-143, https://doi.org/10.1016/S0021-9673(00)00901-8 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]

Chen and Feng, 2007
Chen, Y.; Feng, C., QSPR study on gas chromatography retention index of some organic pollutants, Comput. Appl. Chem. (China), 2007, 24, 10, 1404-1408. [all data]


Notes

Go To: Top, Gas Chromatography, References