Indole, 3-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase EC-1000Polyethylene glycol (Free Fatty Acid Phase)Polyethylene glycol (Free Fatty Acid Phase)DB-FFAPDB-Wax
Column length (m)  30.30.30.30.
Carrier gas     He
Substrate      
Column diameter (mm)  0.250.250.320.32
Phase thickness (μm)    0.250.25
Program not specifiednot specifiednot specified40C(2min) => 40C/min => 60C(2min) => 6C/min => 180C => 15C/min => 230C(10min)40 0C (2 min) 6 K/min -> 190 0C 12 K/min -> 240 0C
I 2530.2495.2510.2484.2495.
ReferenceDelabre and Bendall, 9999Harraca, Syed, et al., 2009Harraca, Syed, et al., 2009Buettner, 2007Steinhaus and Schieberle, 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase DB-FFAPDB-FFAPDB-WaxFFAP
Column length (m) 30.30. 30.
Carrier gas HeHe He
Substrate     
Column diameter (mm) 0.320.32 0.32
Phase thickness (μm) 0.250.25 0.25
Program 40C (2min) => 40C/min => 60C(2min) => 6C/min => 180C => 15C/min => 230C(10min)40C(2min) => 40C/min => 60C(2min) => 6C/min => 180C => 15C/min => 230C (10min)not specified35C (2min) => 40C/min => 60C (2min) => 6C/min => 180C => 10C/min => 240C
I 2484.2484.2496.2494.
ReferenceBuettner and Welle, 2004Buettner, 2004Peterson and Reineccius, 2003Schermann and Schieberle, 1997
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Delabre and Bendall, 9999
Delabre, M.-L.; Bendall, J.F., Flavour ingredients from fermented dairy streams, Expression of Multidisciplinary Flavour Sci., 9999, 375-378. [all data]

Harraca, Syed, et al., 2009
Harraca, V.; Syed, Z.; Guerin, P.M., Olfactory and behavioural responces of tsetse flies, Glossina spp., to rumen metabolites, J. Comp. Physiol. A, 2009, 195, 9, 815-824, https://doi.org/10.1007/s00359-009-0459-y . [all data]

Buettner, 2007
Buettner, A., A selective and sensitive approach to characterize odour-active and volatile constituents in small-scale human milk samples, Flavour Fragr. J., 2007, 22, 6, 465-473, https://doi.org/10.1002/ffj.1822 . [all data]

Steinhaus and Schieberle, 2005
Steinhaus, M.; Schieberle, P., Characterization of odorants causing an atypical aroma in white pepper powder (Piper nigrum L.) based on quantitative measurements and orthonasal breakthrough thresholds, J. Agric. Food Chem., 2005, 53, 15, 6049-6055, https://doi.org/10.1021/jf0506030 . [all data]

Buettner and Welle, 2004
Buettner, A.; Welle, F., Intra-oral detection of potent odorants using a modified stir-bar sorptive extraction system in combination with HRGC-O, known as the buccal odour screening system (BOSS), Flavour Fragr. J., 2004, 19, 6, 505-514, https://doi.org/10.1002/ffj.1473 . [all data]

Buettner, 2004
Buettner, A., Investigation of potent odorants and afterodor development in two chardonnay wines using the Buccal Odor Screening System (BOSS), J. Agric. Food Chem., 2004, 52, 8, 2339-2346, https://doi.org/10.1021/jf035322b . [all data]

Peterson and Reineccius, 2003
Peterson, D.G.; Reineccius, G.A., Determination of the aroma impact compounds in heated sweet cream butter, Flavour Fragr. J., 2003, 18, 4, 320-324, https://doi.org/10.1002/ffj.1228 . [all data]

Schermann and Schieberle, 1997
Schermann, P.; Schieberle, P., Evaluation of key odorants in milk chocolate and cocoa mass by aroma extract dilution analyses, J. Agric. Food Chem., 1997, 45, 3, 867-872, https://doi.org/10.1021/jf960670h . [all data]


Notes

Go To: Top, Normal alkane RI, polar column, custom temperature program, References