1-Propanol, 2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedCapillaryCapillaryCapillaryCapillary
Active phase PMS-1000HP-101SE-30SE-30SE-30
Column length (m) 2.50.   
Carrier gas N2H2   
Substrate Chromaton N-AW-DMCS    
Column diameter (mm)  0.2   
Phase thickness (μm)  0.2   
Temperature (C) 90.60.100.60.80.
I 596.617.93629.629.609.
ReferenceArutyunov, Kudryashov, et al., 2004Garay, 2000Tarjan, Nyiredy, et al., 1989Tarjan, Nyiredy, et al., 1989Tarjan, Nyiredy, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SE-30SE-30SE-30SE-30
Column length (m) 25.25.25.25.25.
Carrier gas      
Substrate      
Column diameter (mm) 0.330.330.330.330.33
Phase thickness (μm)      
Temperature (C) 100.120.140.60.80.
I 629.641.620.629.609.
ReferenceHaken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985Haken and Korhonen, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SE-30SE-30SE-30SE-30
Column length (m) 25.25.25.25.25.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm) 0.330.330.330.330.33
Phase thickness (μm)      
Temperature (C) 100.120.140.60.80.
I 629.641.620.629.609.
ReferenceHaken, Madden, et al., 1985Haken, Madden, et al., 1985Haken, Madden, et al., 1985Haken, Madden, et al., 1985Haken, Madden, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase SE-30SE-30Porapack QSE-30Apiezon L
Column length (m) 3.2. 3.7 
Carrier gas Ar N2  
Substrate Gas Chrom Q (80-100 mesh)Gaschrom Q Celatom AW silanizedCelite 545
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 150.100.200.150.120.
I 605.601.586.595.584.
ReferenceTiess, 1984Winskowski, 1983Goebel, 1982Haken, Nguyen, et al., 1979Bogoslovsky, Anvaer, et al., 1978
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Apiezon LSE-30Apiezon LSqualaneSqualane
Column length (m)  1.3.  
Carrier gas  ArCH4  
Substrate Celite 545Chromosorb W AW DMCS HP (80-100 mesh) Chromosorb GChromosorb G
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 160.100.100.50.70.
I 585.612.609.589.580.
ReferenceBogoslovsky, Anvaer, et al., 1978Pías and Gascó, 1975Wagaman and Smith, 1971Mira and Sanchez, 1970Mira and Sanchez, 1970
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase SE-30
Column length (m) 2.
Carrier gas  
Substrate Chromosorb W
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 100.
I 612.
ReferenceZarazir, Chovin, et al., 1970
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Arutyunov, Kudryashov, et al., 2004
Arutyunov, Y.I.; Kudryashov, S.Y.; Onuchak, L.A., Analysis of Mixtures Containing Unknown Components by Gas Chromatography: Determination of Molecular Mass, J. Anal. Chem. USSR (Engl. Transl.), 2004, 59, 4, 358-365. [all data]

Garay, 2000
Garay, F., Application of a flow-tunable, serially coupled gas chromatographic capillary column system for the analysis of complex mixtures, Chromatographia Sup., 2000, 51, 1, s108-s120, https://doi.org/10.1007/BF02492792 . [all data]

Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8 . [all data]

Haken and Korhonen, 1985
Haken, J.K.; Korhonen, I.O.O., Gas-liquid chromatography of homologous esters. XXIX. Propanoyl and monochlorpropanoyl esters of lower saturated branched-chain and unsaturated alcohols, J. Chromatogr., 1985, 324, 343-353, https://doi.org/10.1016/S0021-9673(01)81333-9 . [all data]

Haken, Madden, et al., 1985
Haken, J.K.; Madden, B.G.; Korhonen, I.O.O., Gas chromatography of homologous esters. XXXI. Butanoyl and monochlorobutanoyl esters of lower saturated branched chain and unsaturated alcohols on SE-30 and OV-351 capillary columns, J. Chromatogr., 1985, 325, 61-73, https://doi.org/10.1016/S0021-9673(00)96008-4 . [all data]

Tiess, 1984
Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]

Winskowski, 1983
Winskowski, J., Gaschromatographische Identifizierung von Stoffen anhand von Indexziffem und unterschiedlichen Detektoren, Chromatographia, 1983, 17, 3, 160-165, https://doi.org/10.1007/BF02271041 . [all data]

Goebel, 1982
Goebel, K.-J., Gaschromatographische Identifizierung Niedrig Siedender Substanzen Mittels Retentionsindices und Rechnerhilfe, J. Chromatogr., 1982, 235, 1, 119-127, https://doi.org/10.1016/S0021-9673(00)95793-5 . [all data]

Haken, Nguyen, et al., 1979
Haken, J.K.; Nguyen, A.; Wainwright, M.S., Application of linear extrathermodynamic relationships to alcohols, aldehydes, ketones, amd ethoxy alcohols, J. Chromatogr., 1979, 179, 1, 75-85, https://doi.org/10.1016/S0021-9673(00)80658-5 . [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Pías and Gascó, 1975
Pías, J.B.; Gascó, L., GC Retention Data of Alcohols and Benzoyl Derivatives of Alcohols, J. Chromatogr. - Chrom. Data, 1975, d14-d16. [all data]

Wagaman and Smith, 1971
Wagaman, K.L.; Smith, T.G., Use of hydrocarbons as carrier gases in GLC, J. Chromatogr. Sci., 1971, 9, 4, 241-244, https://doi.org/10.1093/chromsci/9.4.241 . [all data]

Mira and Sanchez, 1970
Mira, J.M.; Sanchez, L.G., Polarity of the Gas Chromatographic Stationary Phases and Retention Indices of Aliphatic Esters, Ketones and Alcohols, Anal. Chim. Acta., 1970, 50, 2, 315-321, https://doi.org/10.1016/0003-2670(70)80071-X . [all data]

Zarazir, Chovin, et al., 1970
Zarazir, D.; Chovin, P.; Guiochon, G., Identification of hydroxylic compounds and their derivatives by gas chromatography, Chromatographia, 1970, 3, 4, 180-195, https://doi.org/10.1007/BF02269018 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References