potassium sulfate


Gas phase thermochemistry data

Go To: Top, Condensed phase thermochemistry data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Quantity Value Units Method Reference Comment
Δfgas-1094.12kJ/molReviewChase, 1998Data last reviewed in June, 1978
Quantity Value Units Method Reference Comment
gas,1 bar366.14J/mol*KReviewChase, 1998Data last reviewed in June, 1978

Gas Phase Heat Capacity (Shomate Equation)

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

View table.

Temperature (K) 3000. to 6000.
A 156.9912
B 0.548543
C -0.110834
D 0.007664
E -7.906756
F -1163.244
G 522.4101
H -1094.116
ReferenceChase, 1998
Comment Data last reviewed in June, 1978

Condensed phase thermochemistry data

Go To: Top, Gas phase thermochemistry data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Quantity Value Units Method Reference Comment
Δfliquid-1393.67kJ/molReviewChase, 1998Data last reviewed in June, 1978
Quantity Value Units Method Reference Comment
liquid,1 bar211.42J/mol*KReviewChase, 1998Data last reviewed in June, 1978
Quantity Value Units Method Reference Comment
Δfsolid-1437.71kJ/molReviewChase, 1998α phase; Data last reviewed in June, 1978

Liquid Phase Heat Capacity (Shomate Equation)

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

View table.

Temperature (K) 1342. to 3000.
A 201.4604
B 0.000000
C 0.000000
D 0.000000
E 0.000000
F -1471.274
G 415.5017
H -1393.669
ReferenceChase, 1998
Comment Data last reviewed in June, 1978

Solid Phase Heat Capacity (Shomate Equation)

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

View table.

Temperature (K) 298. to 1200.298. to 1342.
A 139.5050114.3424
B -1.19988481.29554
C 136.8080-0.000942
D -47.14322-0.016197
E -1.6639990.000141
F -1485.964-1461.948
G 329.6528306.4152
H -1437.706-1424.246
ReferenceChase, 1998Chase, 1998
Comment α phase; Data last reviewed in June, 1978 β phase; Data last reviewed in June, 1978

References

Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas phase thermochemistry data, Condensed phase thermochemistry data, References