Benzene, bromo-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase CP-Wax 52CBDB-WaxDB-WaxDB-WaxDB-Wax
Column length (m) 50.30.30.30.30.
Carrier gas  N2N2N2N2
Substrate      
Column diameter (mm) 0.320.2350.2350.2350.235
Phase thickness (μm)  0.50.50.50.5
Tstart (C) 60.100.100.50.50.
Tend (C) 220.    
Heat rate (K/min) 4.10.5.10.5.
Initial hold (min) 5.    
Final hold (min) 30.    
I 1330.1381.031373.681358.591348.92
ReferenceChevance and Farmer, 1999Gerbino and Castello, 1995Gerbino and Castello, 1995Gerbino and Castello, 1995Gerbino and Castello, 1995
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase Carbowax 20M
Column length (m) 3.05
Carrier gas He
Substrate Supelcoport
Column diameter (mm)  
Phase thickness (μm)  
Tstart (C) 40.
Tend (C) 210.
Heat rate (K/min) 10.
Initial hold (min) 10.
Final hold (min) 30.
I 1391.
ReferenceBuchman, Cao, et al., 1984
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chevance and Farmer, 1999
Chevance, F.F.V.; Farmer, L.J., Identification of major volatile odor compounds in frankfurters, J. Agric. Food Chem., 1999, 47, 12, 5151-5160, https://doi.org/10.1021/jf990515d . [all data]

Gerbino and Castello, 1995
Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 1995, 699, 1-2, 161-171, https://doi.org/10.1016/0021-9673(95)00024-H . [all data]

Buchman, Cao, et al., 1984
Buchman, O.; Cao, G.-Y.; Peng, C.T., Structure assignment by retention index in gas-liquid radiochromatography of substituted cyclohexenes, J. Chromatogr., 1984, 312, 75-90, https://doi.org/10.1016/S0021-9673(01)92765-7 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, polar column, temperature ramp, References